Lanzhou Electrostatic precipitator
1. Introduction
1.1. Purpose
As a kind of flue gas purification equipment, electrostatic precipitator is widely used in thermal power generation, iron and steel, non-ferrous metallurgy, chemical industry, building materials, machinery, electronics and other industries.
1.2. Model meaning
R-W-D-fh/XJKC-1-291.2×2×4-2
R -- usage code (R is coal-fired power generation industry; y is metallurgy industry; J is building material industry; h is chemical industry; t is other industry)
W -- form code (W for horizontal; l for vertical)
D ------- electrostatic precipitator
FH -------- characteristic symbol (F for auxiliary electrode; h for transverse slot plate; g for high temperature type)
XJKC -------- user name code
1 ---- Furnace number
291.2 ---- Flow section area of single electrostatic precipitator
First 2 -------- number of rooms of single electrostatic precipitator
4 ---- Electric field number of single chamber of single electrostatic precipitator
Second 2 ----The number of electrostatic precipitators for 1 furnace
1.3. Structural features
Electrostatic precipitator is composed of two parts: dust collector body and power supply device.
According to the nature of flue gas and dust, the high-voltage power supply device of electrostatic precipitator can adjust the maximum voltage of electrostatic precipitator at any time, so that it can keep running when the average voltage is lower than spark discharge voltage. Thyristor controlled high voltage silicon rectifier is usually used in China, which can convert AC power frequency into high voltage direct current and control spark frequency.
Electrostatic precipitator (ESP) body is a place for dust purification, usually steel structure. At present, the most widely used is the plate horizontal electrostatic precipitator. Its body is mainly composed of inlet flue gas box, shell, ash storage system, stair platform, dust collector, discharge electrode, rapping device, trough plate system, heat preservation of protective shell, top lifting, outlet flue gas box (including slot plate), steel pillar, etc.
1.4. Working principle
The main working parts of electrostatic precipitator are discharge electrode and dust collector. When the discharge electrode is connected with high-voltage direct current, an extremely uneven high-voltage electric field is established between the two electrodes, so that the gas between the electrodes is ionized, and then positive ions, negative ions and free electrons are generated. The positive ions are driven to the electrode and finally neutralized; free electrons are attached to the gas molecules to form negative ions. In this way, the flue gas dust particles entering the electric field will be collided and charged by these negative ions according to a certain probability, and then the charged dust particles will drive into the anode plate under the action of the electric field force, and finally adhere to the anode plate. When the dust particles accumulate to a certain thickness, it is necessary to use the external vibration to make it peel off from the anode plate surface and falls into the ash hopper by gravity to achieve the function of ash removal. Otherwise, when the dust on the anode plate accumulates to a certain thickness, the westward separation between the two poles becomes smaller, and the electrical conditions will deteriorate, resulting in the decrease of dust removal efficiency. Therefore, in order to ensure the high-efficiency operation of the dust collector, it is necessary to regularly vibrate the dust to ensure the anode plate clean.
2. Main design parameters
The main design parameters of electrostatic precipitator are shown in table 12-1
Table 12-1 main design parameters of electrostatic precipitator
| No. | Item | No. | Item |
| 1 | Unit capacity(MW) | 18 | Number of electric fields |
| 2 | Rated boiler evaporation capacity(t/h) | 19 | Total dust collection area(m2) |
| 3 | Flue flow(m3/h) | 20 | Comparing dust collection area【m2/(m3/s)】 |
| 4 | Flue temperature(℃) | 21 | Driving speed(cm/s) |
| 5 | Number of distribution dust collectors for 1 boiler (set) | 22 | Bear negative pressure(Pa) |
| 6 | Flow area of single unit(m2) | 23 | Body pressure drop(Pa) |
| 7 | Velocity of flue in electric field(m/s) | 24 | Body air leakage rate(%) |
| 8 | Residence time of flue in electric field(s) | 25 | Dust concentration of inlet flue(g/m3) |
| 9 | Same pole spacing(mm) | 26 | Noise |
| 10 | Length of single electric field(m) | 27 | Dust concentration of flue at electrostatic precipitator outlet (standard state)(mg/m3) |
| 11 | Single electric field width(m) | 28 | Dust removal efficiency (including design efficiency, guarantee efficiency and check coal quality efficiency) (%) |
| 12 | Height of dust collecting plate(m) | 29 | Model and specification of high voltage power supply equipment |
| 13 | Form of dust collecting plate | 30 | Rated DC output voltage (kV) |
| 14 | Rapping mode of dust collector | 31 | Rated DC output current (A) |
| 15 | Discharge electrode form | 32 | Number of high voltage silicon rectifier equipment (set) |
| 16 | Discharge electrode rapping mode | 33 | Model and specification of upper computer control system |
| 17 | Number of flue gas channels per unit | 34 | Smoke and dust continuous monitoring system number specification |
3. Equipment appearance
The shape of the precipitator body is shown in Figure 12-1

4. Selection method
LD brand electrostatic precipitator manufacturers usually use computers to select the type of electrostatic precipitator, that is, according to decades of accumulated experience in the design and production of electrostatic precipitators, the parameters, media data, fly ash characteristics of electrostatic precipitators that have been successfully operated in various places for several years are input into the computer to form software: when it is necessary to select the type of electrostatic precipitator, only the required design is needed The relevant data of electrostatic precipitator are input into the computer one by one, and the best design scheme of electrostatic precipitator can be optimized by using the comparison method. In addition, the analogy method can also be used to select the type. According to the various original data of the new project, the type selection is made by comparing the projects that have been successfully operated in the database.
5. Scope of supply and ordering instructions
5.1. Scope of supply
5.1.1. Equipment. The equipment supplied includes the precipitator body (from the front to the flange of the inlet smoke box, from the back to the flange of the outlet smoke box, and down to the lower flange of the ash hopper), the auxiliary equipment within the whole set, the electrical equipment of the dust collector, the auxiliary equipment of the ash hopper (the material level meter of the ash hopper, the gasification plate and the ash hopper heating device) and the connecting parts (the pipeline and the embedded parts such as the anchor bolt).
5.1.2. Spare parts. The spare parts provided include insulating porcelain sleeve, porcelain shaft, electric heater, material level meter, anode plate, anode hammer, anode bearing, wear-resistant sleeve, rigid pole wire, cathode vibrating hammer, cathode bearing, microcomputer master controller of high-voltage cabinet, relay board, fuse, silicon stack of rectifier transformer, damping resistance, primary and secondary ammeter, primary and secondary voltmeter, etc.
5.2. Ordering instructions
If users want to use LD electrostatic precipitator as dust removal method of coal-fired boiler, they should provide the following information:
5.2.1. Design conditions and environmental conditions.
5.2.1.1. technical parameters of boiler, including boiler type, pulverizing system, maximum continuous evaporation, maximum coal consumption, etc.
5.2.1.2. type of air preheater.
5.2.1.3. slag removal method.
5.2.1.4. ash removal mode.
5.2.1.5. type of induced draft fan.
5.2.1.6. coal properties, including coal type and coal quality analysis data.
5.2.1.7. coal ash properties, including the content of various substances in the ash slag, fly ash particle size analysis, fly ash specific resistance, fly ash density and repose angle.
5.2.1.8. flue gas properties (boiler MCR condition), including flue gas temperature, flue gas volume and dust content at the inlet of dust collector.
5.2.1.9. meteorological and geographical conditions of the plant site.
5.2.1.10. site conditions.
If the following dimensions are limited, they shall be indicated in the bidding document: ① the distance between the electrostatic precipitator inlet and the electrostatic precipitator outlet; ② the width dimension of the electrostatic precipitator (including the stairs on both sides); ③ the elevation of the center of the electrostatic precipitator inlet and the outlet of the electrostatic precipitator; ④ the elevation of the flange under the ash hopper of the electrostatic precipitator.
5.2.2. Technical performance requirements, including electrostatic precipitator guarantee efficiency, body resistance, body air leakage rate, design pressure, steel structure design temperature, service life and design and manufacturing specifications and standards.