PRODUCTS CENTER
Sri Lanka SDQ partial rotation and SDJ angle stroke valve actuator
Category:
Product Description
SDQ series partial rotation and sdj series electric actuator for angle stroke valve
1. Introduction
1.1. Purpose
SDQ series partial rotation and sdj series angular stroke valve electric actuators are used to open and close butterfly valves, ball valves, baffles and other valves with 90 ° stroke angle. The products are mainly used in thermal power generation, water supply and drainage, ships, municipal engineering and other industrial departments. SDQ (B) flame-proof series of partial rotation and sdj series of angle stroke valve electric actuators are mainly used in industrial places with explosive gas in the environment, such as Petrochemical Department, with the flame-proof grade of dⅡBT4
1.2. Model meaning
SD**##-&&
SD --- code of electric actuator
**---------The letter Q (b) indicates partial rotation (flameproof); the letter J (b) indicates angular stroke (flameproof)
##------------Output torque (n · m)
&&---------------90 ° full stroke time (s)
1.3. Structural features
1.3.1. Structure description. The electric actuator of SDQ valve is composed of motor, deceleration mechanism, control mechanism, hand wheel and mechanical limit. The control mechanism is composed of stroke control mechanism, torque limiting mechanism, opening indication mechanism and mechanical limit mechanism, which is used to control the opening, closing and valve position indication of the valve. The main drive principle of SDQ is shown in figure 68-1.
During the electric operation, the power and motion output by the motor are input into the eccentric arm through a pair of spur gears E and F after deceleration and torque increase, and then output by the output internal gear A after deceleration and torque increase through NN type planetary gear drive with small tooth difference (B, D, C, A); During manual operation, the manual force is increased by a pair of worm gear rod pairs G and B', and then output by output internal gear A through NN type planetary gear drive with small tooth difference (B, D, C, A).
1.3.2. Description of important parts:
1.3.2.1. The stroke control mechanism adopts the cam structure, the camshaft is synchronized with the output shaft, and four cams are installed on the camshaft to touch four four wire micro switches respectively. Among them, the lower cam is used to control the "off" direction of the valve (four wire microswitch labels are S1 and S3), and the upper cam is used to control the "open" direction of the valve (four wire microswitch labels are S2 and S4). When the electric actuator works, the cam rotates. When the cam touches the microswitch and makes its contact move, the motor stops rotating. The stroke of the valve can be changed by changing the rotation angle of the cam. The cam is equipped with a set screw to fasten the adjusted cam position.
1.3.2.2. The switch of the torque limiting mechanism has one in each of the two rotation directions of the output shaft, and the cutting torque of each electric actuator has been set before leaving the factory.
1.3.2.3. Opening indication mechanism. An opening indicating shaft and an opening indicating component are installed on the top of the camshaft of the stroke control mechanism, and the cover is provided with marks indicating the closed position and open position of the valve. When the electric actuator works, the opening pointer and the output shaft rotate synchronously, and the position where the opening pointer is aligned is the opening degree of the valve.
1.3.2.4. The mechanical limit is used to limit the limit position of "open" and "close" of the valve, which can prevent the valve from opening or closing beyond the limit. Its structure is that two screws are set on the box, and the limit position of the valve switch can be changed by adjusting the screw depth of the two screws.
1.3.2.5. The hand wheel is used to manually open and close the valve. The hand / electric switching mechanism of SDQ is of full-automatic structure. Manual operation can be carried out without manual switching. The valve can be opened or closed by turning the hand wheel, and electric operation can be realized by energizing.
1.3.3. Important characteristics:
1.3.3.1. Compact structure, small volume and light weight.
1.3.3.2. The shell is made of high strength aluminum alloy by die casting.
1.3.3.3. The motor has the function of overheating protection
1.3.3.4. The main transmission mechanism is composed of a pair of spur gears and NN type planetary gear transmission mechanism with small tooth difference.
1.3.3.5. Automatic hand / electric switching mechanism.
1.3.3.6. With mechanical moment protection and mechanical limit.
1.3.3.7. The cover is equipped with plug-in terminals for field wiring.
1.3.3.8. Valve position indicator is provided outside the cover.
2. Main technical parameters and product appearance
2.1. Main technical parameters (see table 68-1)
Table 68-1 main technical parameters of SDQ series partial rotation and sdj series angular stroke valve electric actuator
| Model | Rated torque | Output speed | 90° full stroke time | Wheel operation force | Manual ratio | Motor power | Weight |
| (N·m) | (r/ min) | (s) | (N) | (w) | (kg) | ||
| SDQ/J(B)6-6 | 60 | 2.5 | 6 | 20 | 65 | 75 | 16 |
| SDQ/J(B)9-6 | 90 | 2.5 | 6 | 30 | 65 | 75 | 17 |
| SDQ/J(B)6-18 | 60 | 0.83 | 18 | 20 | 65 | 20 | 16 |
| SDQ/J(B)9-18 | 90 | 0.83 | 18 | 30 | 65 | 20 | 16 |
| SDQ/J(B)13-18 | 130 | 0.83 | 18 | 45 | 65 | 40 | 16 |
| SDQ/J(B)25-18 | 250 | 0.83 | 18 | 80 | 65 | 75 | 17 |
| SDQ/J(B)50-18 | 500 | 0.83 | 18 | 90 | 72 | 150 | 28 |
| SDQ/J(B)80-18 | 800 | 0.83 | 18 | 150 | 72 | 240 | 28 |
2.2. Product appearance
2.2.1. The outline and corresponding dimensions of SDQ (B) 6 ~ SDQ (B) 80 are shown in figure 68-2 and table 68-2 respectively.

Table 68-2 dimensions of SDQ (B) 6 ~ SDQ (B) 80
| Model | A | A ' | B | C | D | E | ∮F | G | H | l | J | J ' | K |
| SDQ6-6 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ9-6 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ6-18 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ9-18 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ13-18 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ25-18 | 285 | 355 | 238 | 260 | 192 | 57 | ∮160 | 125 | 80 | 119 | 312 | 485 | 93 |
| SDQ50-18 | 375 | 445 | 292 | 346 | 272 | 83 | ∮250 | 145 | 109 | 141* | 372* | 590 | 111 |
| SDQ80-18 | 375 | 445 | 292 | 346 | 272 | 83 | ∮250 | 145 | 109 | 141* | 372* | 590 | 111 |
*When the output interface of SDQ (B) 50 and SDQ (B) 80 is F10, I = 165, J= 396, J'= 610, and A' is the length of the terminal box with local button.
2.2.2. See figure 68-3 and table 68-3 for SDQ (B) installation connection dimensions (the keyway position shown in the figure is the terminal position of valve opening or closing).

Table 68-3 installation and connection dimensions of SDQ (B) (mm)
| Model | d1 | d3 | d2 | d5 | d6 | h | h1 | h2 | h3 | b | k | α | n-d4 | Remark |
| SDQ6-6 | 65 | 50 | 35 | 31 | 22 | 15 | 3 | 3 | 30 | 6 | 24.8 | 90 | 4-M6 | F05 |
| SDQ6-18 | ||||||||||||||
| SDQ9-6 | ||||||||||||||
| SDQ9-18 | ||||||||||||||
| SDQ13-18 | 90 | 70 | 55 | 45 | 28 | 15 | 3 | 3 | 35 | 8 | 31.3 | 90 | 4-M8 | F07 |
| SDQ25-18 | 125 | 102 | 70 | 54 | 42 | 20 | 3 | 3 | 43 | 12 | 45.3 | 90 | 4-M10 | F10 |
| SDQ50-18 | 125 | 102 | 70 | 60 | 42 | 20 | 3 | 3 | 43 | 12 | 45.3 | 90 | 4-M10 | F10 |
| SDQ80-18 | 150 | 125 | 85 | 70 | 50 | 20 | 3 | 3 | 52 | 14 | 53.8 | 90 | 4-M12 | F12 |
2.2.3. See figure 68-4 and figure 68-5 for the outline and installation connection dimensions of SDJ(B).


2.2.4. Wiring ring of electrical terminal. The 10 kinds of wiring diagrams shown in Fig. 68-6 ~ Fig. 68-15 are electrical terminal wiring diagrams of standard control forms. Other control requirements or forms can be ordered specially.





3. Selection method
Supply method: when ordering, select the appropriate parameters from the following order parameters according to the actual situation. The code definition is shown in table 68-4.
Code position 1 2 3 4 5 6 7 8 9 10
SD ** ## - $$ - @@ && ** ※※ §§ - Z¢¢ ☆☆
**---------- Cctuator class code (Code position 1)
##------------Output torque (Code position 2)
$$--------- 90 ° stroke time (Code position 3)
@@------------------Signal components (Code position 4)
&&--------------------Supply voltage (Code position 5)
**------------- Control form (Code position 6)
※※--------- Contact signal (Code position 7)
§§--------- Connection form (Code position 8)
¢¢☆☆------Special code (Code position 9, 10)
Specific model and significance of 68-4 SDQ Series Partial slewing and SDJ series angular stroke valve electric actuator.
Table 68-4
| Code position | Definition | Code | Remark |
| 1 | Actuator type | Q | Standard partial rotation electric actuator |
| QB | Flameproof partial rotary electric actuator | ||
| J | Angular stroke electric actuator | ||
| JB | Flameproof angular stroke electric actuator | ||
| 2 | Output torque (N·m) | 6 | 60 |
| 9 | 90 | ||
| 13 | 130 | ||
| 25 | 250 | ||
| 50 | 500 | ||
| 80 | 800 | ||
| 3 | 90° stroke time | 6 | 6S (optional only when the output torque is 60N · m and 90N · m) |
| 18 | 18s | ||
| 4 | Signal components | 0 | Without potentiometer RP |
| 1 | With potentiometer RP (1K), adjustable type is required | ||
| 9 | Others | ||
| 5 | Power supply voltage | 0 | Single phase 220 V, 50 Hz (below 130 n · m optional) |
| 1 | Three phase 380V, 50 Hz | ||
| 6 | Control type | 4 | Standard type |
| 0 | Switch type | ||
| 1 | Adjusting type | ||
| 2 | Switch type | ||
| 3 | Adjusting type | ||
| 7 | Contact signal | 0 | 2DE (torque switch) + 2WE (travel switch) |
| 1 | 2DE (torque switch) + 4WE (travel switch) | ||
| 8 | Connection form | 0 | F05 |
| 1 | F07 | ||
| 2 | F10 | ||
| 3 | F12 | ||
| A | Bracket installation, arm output | ||
| 9 | Other connection forms | ||
| 9 | Special order code | ** | Special order code serial number |
Note: when ordering, select the standard control form and mechanical interface size according to figure 68-6 ~ figure 68-15 and figure 68-3. The connection form of angular stroke electric actuator (code position 8) can only select a, and other control requirements of users can be ordered specially.