Syria XTJ-11-300 Electric Actuator

Product Description

XTJ-11-300 Electric Actuator

 

1. Overview

XTJ-11-300 electric actuator is new electric drive reciprocate machine, which is applicable in advance and retract movement of oil gun, spark rod, and flame detector in ignition system. This machine is agile, stable and easy to handle.

         Code illustration:

        XTJ-1 1-300

        X---- Xuzhou Actuator

        First 1----- Power: Eelectric

        Second 1----- Installation: 1- Flange mounting; 2- Base mounting

        300----- Stroke (mm): 300mm.

 

2. Technical data

 

Model XTJ-11-300
Thrust forceN 1000
Thrust speed mm / s 100
Strokemm 300
Motor model YS7124
Motor power (W) 370
Motor speed (rpm) 1400
Motor voltage (V) AC380
Motor current (A) 1.12
Installation type Flange
Weight (Kg) 25

 

3. Structure and Principle

The actuator consists of electromotor, thread bar and nut, thrust bar, bumper and stroke switch. Axis joint drives and turns thread bar and nut from whirligig to linear movement, then sends to handspike, this process accomplished the advance and retract movement of electromotor.

 

4. Installation, Regulating, and Maintenance

4.1. Installation and Regulating

4.1.1. Install electromotor and stroke switch following wiring drawing.

4.1.2. For spark rod mounting, insert its head into oil gun atomizing region for 40 ~60mm. (See the following figure)

4.1.3. After mounting, parallelize oil gun/spark rod and motorial direction of thrust bar so as to make sure smooth movement and low noise.

4.1.4. See the actuator figure for its mounting size. (Drawing 1)

4.2. Usage and Maintenance

4.2.1. Actuator works under temperature -25 ℃~80℃, and 85% humidity.

4.2.2. If actuator is unavailable, please check the position of stroke switch and adjust the circuit.

4.2.3. Examine the actuator annually, and inject lubricant to thread bar and axis of rotation.

4.2.4. Do not step on or put stress on the actuator.

 

5. Troubles and Troubleshooting

Troubles Cause Troubleshooting
Oil gun or spark rod off 1. Loose of bolt 1. Fasten the bolt
2. Oil gun/spark rod block in tube 2. Remove block
No position feedback signal 1. Loose stroke switch wire 1. Rewiring
2. Change position of stroke switch 2. Reset stroke position
3. Stroke switch is broken 3. Change switch
Ignition failed 1. Change position of oil gun or spark rod 1. Reset spark rod/oil gun position
2. Loose or broken of cable joint 2. Fasten or change the joint
3. Broken of HEA exciter 3. Repair or change exciter
4. Burnt spark rod head 4. Change spark rod
Electromotor blocked Stroke switch Disassembly vane and adjust axis and stroke switch, then reset vane and cover.

 

6. Spare Parts

6.1. Stroke switch Z-15GW2-B

6.2. Electric motor YS7124

Model, standard and quantity of spare parts should be prescribed in contract.

 

Get MFG video from the link below: