  • 计量箱LL副本.jpg

LL/LG chemicals metering box

key word:Heat exchange element


Product description

LL, LG chemicals metering box

 

1. Introduction

1.1 purpose

The metering box is used for the measurement of general liquid medicine. The lining measuring tank can be used for the solution with corrosion to metal, and the unlined measuring tank can be used for the liquid medicine without corrosion of metal (such as caustic soda).

1.2 model significance

                  LL4

                 first L -------- storage tank

                second L -------- rubber lining

                 4 -------- effective volume of equipment (M3)

                 LG4

                 L -------- storage tank

                 G -------- steel

                 4 -------- effective volume of equipment (M3)

1.3 structural features

1.3.1 for the lining metering box, the structure adopts type I; for the unlined metering box, when its diameter is greater than 1000, the structure adopts type II.

1.3.2. the lined metering tank can be used for the measurement of hydrochloric acid, coagulant and salt solution; the unlined metering tank can be used for the measurement of sodium hydroxide, concentrated sulfuric acid and phosphate solution.

1.3.3. if it is used for the measurement of concentrated sulfuric acid, the material of liquid level gauge shall not be PVC.

1.3.4. the pressure rating of all interface flanges is PN1.0MPa.

1.3.5. the interface of liquid level gauge is DN25

1.4 product series

See table 30-1 for the product series of ll and LG chemicals metering boxes

Table 30-1 product series of ll and LG chemicals metering boxes

Effective volume Nominal diameter equipment outline dimensionsmm Nozzle diametermm Weightkg
m3 mm H h L D1 D2 a b c d e line with rubber line without rubber
0.1 500 798 450 355 620 400 25 25 32 32 32 105 95
0.16 500 1103 750 355 620 400 25 25 32 32 32 127 113
0.25 600 1173 840 405 720 450 25 25 32 32 32 160 145
0.4 700 1330 990 455 820 525 25 25 32 32 32 205 185
0.63 800 1544 1200 505 920 600 25 25 32 32 32 269 242
1 900 1863 1525 555 1020 675 32 25 50 32 32 365 328
1.25 1000 1882 1540 605 1120 750 32 25 50 32 32 403 361
1.6 1100 1976 1635 656 1220/1144 825 32 25 50 32 32 558 510
2 1200 2061 1710 706 1340/1244 900 32 25 50 32 32 615 558
2.5 1300 2176 1830 756 1440/1340 975 32 25 50 32 32 710 645
3.2 1400 2372 2025 806 1540/1444 1050 32 25 50 32 32 825 748
4 1600 2282 1935 906 1740/1644 1200 50 25 80 50 50 961 873
5 1800 2258 1910 1008 1940/1848 1350 50 25 80 50 50 1347 1245
6.3 2000 2298 1950 1108 2140/2048 1500 50 25 80 50 50 1417 1300

Note: in the table, the score is the data of type I metering box, and the denominator is the type II measurement data.

 

2. Technical parameters

See table 30-2 for technical parameters of ll and LG chemicals metering tanks

Table 30-2 technical parameters of ll and LG chemicals metering boxes

Item Data Item Data
Design pressureMPa <0.1 material of the main body Q235-B
Design temperature(℃) 50 container form vertical
Capacityt/h See table 30-1    

 

3. Equipment appearance and structural dimensions

See Fig. 30-1 and table 30-3 for the outline and structural dimensions of chemicals metering box

Code Nozzle name
a cleaning water pipe
b vent pipe
c liquid inlet pipe
d outlet pipe
e sewage pipe