HTHP straight pipe
key word:Heat exchange element
Category:
Product description
Straight pipe section
1. Introduction
The straight pipe section is mainly used as main pipe and branch pipe of steam water pipe in power station.
2. Main technical parameters
2.1. The design pressure of main steam pipe of subcritical and supercritical units can be taken as the working pressure of superheater outlet under the maximum continuous evaporation capacity of boiler.
2.2. The design pressure of main steam pipe of ultra supercritical unit can be 105% at the inlet of main steam valve (the design pressure at the inlet of main steam valve is 105% of the rated steam inlet pressure of steam turbine) or the design pressure at the inlet of main steam valve plus the pressure drop of the pipe from the outlet of boiler superheater to main steam valve, the larger one is taken.
2.3. The design temperature of main steam pipe and design parameters of other pipes shall be in accordance with DL/T 5366-2006 "technical specification for stress calculation of steam water pipe in thermal power plant" .
3. Selection method
3.1. Piping materials
3.1.1. Subcritical unit:
3.1.1.1. The main steam pipe adopts A335P91 material of ASTM standard.
3.1.1.2. A335P22 material of ASTM standard is adopted for hot section steam pipe.
3.1.1.3. ASTM standard A672B70CL32 material is adopted for cold section steam pipe.
3.1.1.4. 15NiCuMoNb5-6-4 material of EN10216-2 standard is adopted for high pressure water supply pipeline.
3.1.2. Supercritical unit:
3.1.2.1. A335P91 material of ASTM standard shall be adopted for main steam pipe and hot section steam pipe
3.1.2.2. When the design temperature is less than 415 ℃, A672B70CL32 material is used for cold section steam pipe; when the design temperature is more than 415 ℃, A6911-1 / 4CrCL22 material (or other pipe with equivalent performance) is used.
3.1.2.3. 15NiCuMoNb5-6-4 material of EN10216-2 standard is adopted for high pressure water supply pipeline.
3.1.3. Ultra supercritical unit:
3.1.3.1. A335P92 or other pipes with equivalent performance shall be used for main steam pipe and hot section steam pipe. When A335P91 material is used for hot section steam pipe, metal supervision shall be strengthened during operation.
3.1.3.2 for cold section steam pipe, A672B70CL32 material shall be used when the design temperature is less than 415 ℃, and A6911-1 / 4CrCL22 material (or other pipe with equivalent performance) shall be used when the design temperature is more than 415 ℃.
3.1.3.3. 15NiCuMoNb5-6-4 material of EN10216-2 standard is adopted for high pressure water supply pipeline.
3.2. Allowable stress of pipeline
3.2.1. The allowable stress of A335P92 material is determined according to the strength value specified in EN10216-2:2002 and A2:2007 (the strength value is the same as that in ECCC-2005) and the safety factor in DL/T5366-2006
3.2.2. Except for A335P92 material, the allowable stress value in Appendix A of ASME B31.1-2007 is adopted for American pipe; the allowable stress of German pipe is determined according to the strength index of EN10216-2 Technical delivery conditions for pressure seamless steel pipe part 2: non alloy and alloy steel with specified high temperature characteristics and the safety factor specified in DL/T 5366-2006.
3.2.3. The allowable stress of A672B70CL32, A6911-1/4CrCL22, A335P91 and A335P22 materials shall be the value specified in ASME B31.1 - 2007 power piping.
3.3. Physical properties of steel
See table 71-1 for the material characteristic data of the four pipelines.
Table 71-1 material characteristic data of four major pipelines
| Temperature (℃) | Allowable stress | Temperature (℃) | Elastic modulus | Temperature (℃) | Average coefficient of linear expansion |
| (MPa) | (kN/mm2) | (10 -6/ ℃) | |||
| A335P22(wall thickness < 76mm) (ASME B31.1—2007) | |||||
| 20 | 117.8 | 20 | 211 | 20 | 12.5 |
| 343 | 114.4 | 150 | 203 | 150 | 13.4 |
| 371 | 114.4 | 200 | 199 | 200 | 13.6 |
| 399 | 114.4 | 250 | 195 | 250 | 13.8 |
| 427 | 114.4 | 300 | 191 | 300 | 14 |
| 454 | 114.4 | 350 | 187 | 350 | 14.2 |
| 482 | 93.7 | 400 | 182 | 400 | 14.4 |
| 510 | 74.4 | 450 | 175 | 450 | 14.6 |
| 538 | 55.1 | 500 | 165 | 500 | 14.7 |
| 566 | 39.3 | 550 | 153 | 550 | 14.8 |
| 593 | 26.2 | 600 | 137 | 600 | 14.9 |
| A672B70CL32 (ASMEB31.1-2007) | |||||
| 20 | 137.9 | 20 | 202 | 20 | 11.6 |
| 260 | 137.9 | 100 | 197 | 100 | 12.1 |
| 316 | 133.8 | 150 | 194 | 150 | 12.4 |
| 343 | 129.6 | 200 | 190 | 200 | 12.7 |
| 371 | 124.8 | 250 | 188 | 250 | 13 |
| 399 | 102 | 300 | 184 | 300 | 13.3 |
| 427 | 82.7 | 350 | 178 | 350 | 13.6 |
| — | — | 400 | 171 | 400 | 13.8 |
| — | — | 450 | 161 | 450 | 14.1 |
| A6911-1/4CrCL22 (ASMEB31.1-2007) | |||||
| 20 | 117.9 | 20 | 205 | 20 | 11.6 |
| 343 | 117.9 | 150 | 197 | 150 | 12.4 |
| 371 | 117.9 | 200 | 193 | 200 | 12.7 |
| 399 | 117.9 | 250 | 190 | 250 | 13 |
| 427 | 115.8 | 300 | 186 | 300 | 13.3 |
| 454 | 113.1 | 350 | 181 | 350 | 13.6 |
| 482 | 94.5 | 400 | 176 | 400 | 13.8 |
| 510 | 64.1 | 450 | 170 | 450 | 14.1 |
| 538 | 43.4 | 500 | 160 | 500 | 14.3 |
| 566 | 29 | 550 | 148 | 550 | 14.6 |
| A335P91 (wall thickness < 76mm ASMEB31.1-2007) | |||||
| 20 | 167.5 | 20 | 213 | 20 | 10.4 |
| 343 | 161.3 | 150 | 205 | 150 | 11.1 |
| 371 | 157.9 | 200 | 201 | 200 | 11.3 |
| 399 | 153.1 | 250 | 197 | 250 | 11.5 |
| 427 | 146.9 | 300 | 193 | 300 | 11.7 |
| 454 | 140 | 350 | 189 | 350 | 11.8 |
| 482 | 131.7 | 400 | 185 | 400 | 12 |
| 510 | 122.7 | 450 | 181 | 450 | 12.2 |
| 538 | 112.4 | 500 | 176 | 500 | 12.3 |
| 566 | 96.5 | 550 | 171 | 550 | 12.5 |
| 593 | 71 | 600 | 164 | 600 | 12.6 |
| 621 | 48.3 | 650 | 156 | 650 | 12.8 |
| 15NiCuMoNb5-6-4 (1.6368) (WB36) wall thickness < 80mm | |||||
| 20 | 203.3 | 20 | 211 | 100 | 12.2 |
| 200 | 203.3 | 100 | 206 | 200 | 12.9 |
| 250 | 203.3 | 200 | 200 | 300 | 13.4 |
| 300 | 203.3 | 300 | 192 | 400 | 14 |
| 350 | 203.3 | 400 | 184 | 500 | 14.3 |
| 400 | 203.3 | 500 | 175 | — | — |
| 410 | 203.3 | — | — | — | — |
| 420 | 203.3 | — | — | — | — |
| 430 | 200 | — | — | — | — |
| 440 | 182 | — | — | — | — |
| 450 | 163.3 | — | — | — | — |
| 460 | 140 | — | — | — | — |
| 470 | 116.7 | — | — | — | — |
| 480 | 92.7 | — | — | — | — |
| 490 | 69.3 | — | — | — | — |
| 500 | 46 | — | — | — | — |
| A335P92 (X10CrWMoVNb9-2) (1.4901) | |||||
| 20 | 206.7 | 20 | 217 | 50 | 10.6 |
| 500 | 206.7 | 100 | 214 | 100 | 10.7 |
| 510 | 206.7 | 150 | 211 | 150 | 10.9 |
| 520 | 156.7 | 200 | 207 | 200 | 11.1 |
| 530 | 145.3 | 250 | 204 | 250 | 11.2 |
| 540 | 134.7 | 300 | 200 | 300 | 11.4 |
| 550 | 124.7 | 350 | 198 | 350 | 11.5 |
| 560 | 114.7 | 400 | 191 | 400 | 11.7 |
| 570 | 104.7 | 450 | 187 | 450 | 11.9 |
| 580 | 94.7 | 500 | 182 | 500 | 12 |
| 590 | 84.7 | 550 | 176 | 550 | 12.2 |
| 600 | 75.3 | 600 | 170 | 600 | 12.3 |
| 610 | 66.7 | 650 | 164 | 650 | 12.5 |
| 620 | 58 | — | — | — | — |
| 630 | 50 | — | — | — | — |
4. Selection examples
See table 71-2 for pipeline design parameters and recommended specifications (straight pipe) calculated according to the above principles
Table 71-2 pipeline design parameters and recommended specifications (straight pipe)
| Application | Designing data | Material | Material standard | Min.ID X Min wall thickness or OD X wall thickness | Deviation range | ||
| Pressure | Temperature | Pipe diameter | Wall thichness | ||||
| (MPa) | (℃) | ||||||
| Subcritical 300MW Unit | |||||||
| Water supply | 28 | 285 | 15NiCuMoNb5-6-4 | EN 10216-2 | Main: OD355.5X25 | 土1.0% | 士12.5% |
| Branch: OD244.5X20 | 土1.0% | 土12.5% | |||||
| Main steam | 17.5 | 546 | A335P91 | ASTM A335 | Main: ID368X41 | +3.175mm | |
| Branch: ID273X30 | +2.362mm | ||||||
| Cold section | 4.75 | 355 | A672B70CL32 | ASTM A672 | Main: OD812.8X18.5 | 土0.5% | -0,3mm |
| Branch: OD558.8X16 | 士0.5% | -0.3mm | |||||
| Hot section | 4.5 | 546 | A335P22 | ASTM A335 | Main: ID699X35 | +3.962mm | |
| Branch: ID508X24.8 | +3.175mm | ||||||
| Supercritical 600 MW Unit | |||||||
| Ahead Water supply valve | 38 | 193 | 15NiCuMoN65-6-4 | EN 10216-2 | Branch: OD355.6X40 | 士1.0% | 士10% |
| After Water supply valve | 35 | 286 | 15NiCuMoNb5-6-4 | EN 10216-2 | Main: OD 508X50 | 士1.0% | 士12.5% |
| Branch: OD 355.6X40 | 士1.0% | 士10% | |||||
| Main steam | 25.4 | 576 | A335P91 | ASTM A335 | Main: ID419.1X70 | +3.175mm | |
| Branch: ID298.5X50 | +2.362mm | ||||||
| Cold section | 5.42 | 342 | A672B70CL32 | ASTM A672 | Main: OD1016X27 | 士0.5% | -0.5mm |
| Branch: OD711X19 | 士0.5% | -0.5mm | |||||
| Hot section | 5.42 | 573 | A335P91 | ASTM A335 | Main: ID914X31 | +4.749mm | |
| Branch: ID648X23 | +3.962mm | ||||||
| Ultra Supercritical 600 MW Unit | |||||||
| Ahead Water supply valve | 39 | 193 | 15NiCuMoNb5-6-4 | EN 10216-2 | Branch: OD355.6X40 | 士1.0% | 士10% |
| After Water supply valve | 36 | 295 | 15NiCuMoNb5-6-4 | EN 10216-2 | Main: OD508X55 | 士1.0% | 士10% |
| Branch: OD355.6X40 | 士1.0% | 士10% | |||||
| Main steam | 27.46 | 610 | X10CrWMoVNb | EN 10216-2:2002 + A2 : 2007 | Main: ID406X100 | +3.175mm | |
| 9-2(P92) | Branch: ID292X73 | +2.362mm | |||||
| Cold section | 5.7 | 372 | A672B70CL32 | ASTM A672 | Main: OD1016×29 | 士0.5% | -0.5mm |
| Branch: OD711×21 | 士0.5% | -0.5mm | |||||
| 425 | A6911-1/4CrCL22 | ASTM A691 | Main: OD1016×30 | 士0.5% | -0.5mm | ||
| Branch: OD711×22 | 士0.5% | -0.5mm | |||||
| Hot section | 5.7 | 608 | X10CrWMoVNb9-2(P92) | EN 10216-2:2002 + A2 : 2007 | Main: ID883×43 | +4.749mm | |
| Branch: ID616×31 | +3.962mm | ||||||
| Ultra supercritical 1000MW unit | |||||||
| Ahead Water supply valve | 39 | 193 | 15NiCuMoNb5-6-4 | EN 10216-2 | Branch: OD457×50 | 士1.0% | 士10% |
| After Water supply valve | 15NiCuMoNb5-6-4 | EN 10216-2 | Main: OD660×65 | 士1.0% | 士12.5% | ||
| Branch: OD457×50 | 士1.0% | 10% | |||||
| Main steam | X10CrWMOVNb9-2(p92) | ASTM A335 | Main: ID368×92 | +2.362mm | |||
| Branch: ID260×66 | +3.175mm | ||||||
| Cold section | A672B70CL32 | ASTM A672 | Main: OD1219×38 | 士0.5% | -0.5mm | ||
| Branch: OD863.6×27 | 士0.5% | -0.5mm | |||||
| ASTM A691 | Main: OD1219×38 | 士0.5% | -0.5mm | ||||
| Branch: OD863.6×27 | 士0.5% | -0.5mm | |||||
| Hot section | A6911-1/4CrCL22 | EN 10216-2:2002 + A2 : 2007 | Main: OD749×38 | +3.962mm | |||
| Branch: OD527×28 | +3.175mm | ||||||
| Ultra supercritical 1000MW unit | |||||||
| Ahead Water supply valve | 42 | 193 | 15NiCuMoNb5-6-4 | EN 10216-2 | Branch: OD457×55 | 士1.0% | 士10% |
| After Water supply valve | 38 | 302 | 15NiCuMoNb5-6-4 | EN 10216-2 | Main: OD610×65 | 士1.0% | 士10% |
| Branch: OD457×50 | 士1.0% | 士10% | |||||
| Main steam | 28.84 | 610 | X10CrWMoVNb9-2(P92) | EN 10216-2:2002 + A2 : 2007 | Main: ID356×94 | +3.175mm | |
| Branch: ID254×68 | +2.362mm | -0.5mm | |||||
| Cold section | 7.3 | 400 | A672 B70 CL32 | ASTM A672 | Main: OD1168×47 | 士0.5% | -0.5mm |
| Branch: OD813×33 | 士0.5% | -0.5mm | |||||
| 425 | A6911-1/4CrCL22 | ASTM A691 | Main: OD1168×42 | 士0.5% | -0.5mm | ||
| Branch: OD813×30 | 士0.5% | -0.5mm | |||||
| Hot section | 7.3 | 608 | X10CrWMoVNb9-2(P92) | EN 10216-2:2002 + A2 : 2007 | Main: ID686×42 | +3.962mm | |
| Branch: ID495×31 | +3.175mm | ||||||
explain:
① If the design parameters, material standards, pipe diameter and wall thickness deviation of the four major pipelines of subcritical, supercritical and ultra supercritical unit engineering are different from the design parameters, they shall be recalculated.
② For the main steam and reheat steam pipe with design temperature above 600 ℃, the oxidation corrosion allowance can be considered properly. The value of oxidation corrosion allowance in table 71-2 is 1.6 mm.
③ For the wall thickness calculation of inner diameter control seamless pipe (main steam and hot section), the matching requirements should be considered, and the minimum wall thickness = minimum wall thickness + 0.5 (inner diameter deviation + 0.25).
④ For outer diameter seamless pipe (water supply pipe), calculate the wall thickness according to DL/T 5366-2006; in order to meet the requirements of butt welding, use the wall thickness chopper, add about 2.5mm on the basis of the calculated wall thickness, and then rely on the standard wall thickness series. During installation, ensure that the wall thickness of the pipe at the butt joint is not less than the minimum wall thickness.
⑤ For the electric fusion welded steel pipe (cold section), the diameter is larger, and considering the requirements of counterpart and pipe stiffness, the wall thickness can be appropriately increased. The wall thickness increment in table 71-2 is about 0.5% of the outer diameter.
⑥ The wall thickness calculation of A6911-1/4Cr CL22 electric fusion welded steel pipe in table 71-2 adopts the allowable stress of ASTM A387 Class 1 plate.