QLG Condensing Hydrogen Dryer

key word:Heat exchange element


Product description

1. Code:

QLG-VIIA, 

Q-----Hydrogen

L-----condensing

G----Dryer

I, III, IV, V, VI, VII------Versions

A, or S------Water cooling

B, or F------Air cooling

 

Popular models

QLG-V, QLG-VI, QLG-VT, QLG-III, QLG-IIA

 

2. QLG-V condensing hydrogen dryer

QLG-V type condensing hydrogen dryer is a special equipment for hydrogen cooled generator set. Its main purpose is to dry the cooling hydrogen in the hydrogen cooled generator, which can control the humidity of hydrogen within the ministerial standard, so as to avoid the stress change and poor insulation problems caused by high hydrogen humidity, and ensure the safe operation of the generator not affected by high hydrogen humidity.

QLG-V type condensing hydrogen dryer is one of the scientific research achievements of our factory in 2001. This product inherits the characteristics of previous condensing hydrogen dryers, such as large dehumidification capacity, good dehumidification effect, not affected by oil and dust, etc

2.1. Aesthetics: GGD profile is used for overall assembly cabinet structure, fully standardized components, equipment volume is reduced to the minimum, optimized assembly and appearance process design, shell electrostatic spraying, the whole machine is exquisite and beautiful.

2.2. Practicability: the equipment is optimized for all kinds of possible damage of the dryer, which greatly reduces the possibility of failure; All the standardized parts can be disassembled, and the corresponding assembly and overhaul processes are designed, which makes the maintenance and overhaul extremely simple and convenient; In the control aspect, the intelligent control program is adopted, the man-machine interface is added, the text prompt is provided for each step of operation, and all kinds of operation states are clearly indicated, so the operation is simple and convenient; In the dehumidification operation stage, the dryer can dry up to 120N cubic meters of hydrogen per hour, and the dew point of outlet hydrogen under working pressure is - 10 ° C--30 ° C. The application effect is excellent.

2.3. Reliability: select high-quality stainless steel and anti-corrosion raw materials, precision manufacturing, lifetime guarantee. Intelligent control operation, the average time between failures exceeded 10000 hours. The electrical control system adopts explosion-proof design, which can provide safe operation guarantee.

2.4. Environmental protection: the use of environmentally friendly refrigerants and raw materials, high efficiency, low energy consumption, intelligent operation. It is an environmental protection product.

2.5. Advanced nature: intelligent automatic dehumidification operation without any duty. The dehumidifier can be operated by two machines, which makes the dehumidifier work more efficient; All kinds of operation conditions are displayed on the full Chinese screen of the human-machine interface, which is convenient for operation and maintenance; It can be connected to the main control room for centralized control without on-site operation; It can be connected to a remote computer to monitor the operation without on-site operation; It can work with hydrogen pipeline fan and humidity on-line monitor. When the generator stops, it can still dry the hydrogen in the generator. When the hydrogen humidity reaches the standard, it will stop dehumidification operation automatically. When the hydrogen humidity exceeds the standard, it will start dehumidification operation automatically.

 

3. Other types QLG hydrogen dryers.

 

QLG-VI

 

 

4. QLG-III

4.1. Working Principle

4.1.1. Principle Overview.

Condensing hydrogen dryer is to use “refrigeration” to cool down the hydrogen, make its temperature drop below the “dew point”, so that the water vapor in the form of condensation or frost to separate out, so as to achieve the purpose of reducing the humidity of hydrogen.

4.1.2. Principle of refrigeration.

Refrigerant gas from the low-pressure tube is sucked in by the compressor, compressed by the compressor, becomes a high-temperature, high-pressure gas into the condenser, the condenser and the external air (or water) for heat exchange, the refrigerant in the evaporator absorbed heat and the compressor's heat of the work to release, so that the high-temperature, high-pressure refrigerant vapors condensed into high-pressure liquid refrigerant, by the liquid storage (water-cooled equipment, no), the filter drier, Solenoid valve, by the thermal expansion valve to catch the flow of pressure into the evaporator, through the evaporator tube wall to absorb the heat of the condenser hydrogen, boiling vaporization for the gaseous and then through the gas-liquid separator, the liquid refrigerant and gaseous refrigerant is not evaporated to the end of the separation of liquid refrigerant and gaseous refrigerant, liquid refrigerant in the gas-liquid separator to continue to evaporate into the gaseous refrigerant, the gaseous refrigerant through the low-pressure tube and then into the compressor. By the cycle, it constantly absorbes the heat of hydrogen in the cooler to achieve the purpose of hydrogen cooling dehumidification.

4.1.3. Principle of hydrogen dehumidification system.

The hot and humid hydrogen from the generator enters the heat exchanger from the hydrogen inlet pipe, exchanges heat with the low-temperature hydrogen from the cooler back to the heat exchanger, and is preliminarily cooled down and dehumidified, and then enters the cooler and exchanges heat with the refrigerant through the wall of the evaporator tube in the cooler, and is sufficiently dehumidified by deep cooling, and then returns to the heat exchanger and exchanges heat with the hot and humid hydrogen from the generator and is heated up, and finally returns to the generator through the hydrogen outlet pipe.

The water condensed and precipitated in the heat exchanger and the frost formed in the cooler become water after defrosting by electric heating, and then enter the water storage tank through the deposition cylinder. When the water level in the tank reaches a certain height, the water level controller will output a signal and the water level indicator light. At this time, manually turn open the water valve to release the water.

4.1.4. Circulation fan working principle

Circulating fan unit can increase the pressure difference between the hydrogen inlet and outlet, increase the handling capacity of the dried gas, especially in the case of generator maintenance, shutdown, and does not stop the drying effect of gas drying of the hydrogen gas.

 

4.2. Structure
The structure of the equipment can be divided into four parts: refrigeration system, circulating air unit, hydrogen dehumidification system and electrical control system.
4.2.1. The refrigeration system consists of compressor, condenser, liquid reservoir (water-cooled type equipment without), filter drier, solenoid valve, thermal expansion valve, evaporator, gas-liquid separator and so on.
4.2.2. Dehumidification system consists of heat exchanger, cooler, heater, water storage tank, water discharge valve.
4.2.3. Circulation unit consists of fan, leakage tank and valve piping.
4.2.4. The electrical control system consists of human-machine interface, programmable program controller, solid state relay, temperature controller, water level controller and so on.

Download the operation manual for QLG-IIIA from the link below:

https://drive.google.com/file/d/1SW04TbaOjvl-ooJpvsmn3i1F5l47BuDi/view?usp=sharing