PRODUCTS CENTER
Cambodia Porous plate and water cap floating bed ion exchanger
Category:
Product Description
Porous plate and water cap floating bed ion exchanger
1. Introduction
1.1. Purpose
The equipment is a pure water treatment equipment. When the salt content of raw water is less than 500 mg / L, the salt content can be reduced to less than 10 mg / L after passing through the positive floating bed and the negative floating bed; when the salt content of the raw water is more than 500 mg / L, the weak type and strong type resin can be applied for joint operation; when the salt content of raw water is higher, it can also be combined with other pre desalination methods such as reverse osmosis. If the effluent quality is higher, secondary desalination equipment can be set.
Floating bed ion exchanger belongs to counter current regeneration equipment, but its output can be doubled than that of common fixed bed countercurrent regeneration equipment.
1.2. Model meaning
JFL100•200B
J -------- ion exchange
FL -------- floating bed, lining
100 -------- equipment diameter (mm)
200 -------- resin layer height (mm)
B----------Porous plate, water cap type
1.3. Structural features
1.3.1. The inlet and outlet water are in the form of porous plate and water cap.
1.3.2. The equipment is equipped with local sampling device and water inlet and outlet pressure gauges.
1.3.3 the pressure rating of all interface flanges of the equipment is PN1.0MPa
1.3.4. The equipment is equipped with manual rubber lined diaphragm valve or pneumatic rubber lined diaphragm valve.
1.3.5. The valve at resin loading and unloading port is DC rubber lined diaphragm valve or ball valve.
1.3.6 when the equipment diameter DN ≤ 1250, the large flange structure is adopted at the porous plate.
1.3.7. 1751 semi-rigid adhesive for anticorrosion of equipment.
1.4. Product series
The product series of porous plate and water cap floating bed ion exchanger are shown in table 19-1.
Table 19-1 product series of porous plate and water cap floating bed ion exchanger
| Nominal diameter resin layer height item |
DN1000 | DN1250 | DN1600 | DN1800 | ||||||||||||
| 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | |
| JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | |
| 100·200A | 100·250A | 100·280A | 100·320A | 125·200A | 125·250A | 125·280A | 125·320A | 160·200A | 160·250A | 160·280A | 160·320A | 180·200A | 180·250A | 180·280A | 180·320A | |
| design capacity (t/h) | 35 | 50 | 80 | 100 | ||||||||||||
| Resin volume (m3) | 1.57 | 1.96 | 2.2 | 2.51 | 2.45 | 3.07 | 3.44 | 3.93 | 4.02 | 5.03 | 5.63 | 6.43 | 5.1 | 6.36 | 7.12 | 8.14 |
| compressed resin volume (m3) | 0.157 | 0.245 | 0.4 | 0.51 | ||||||||||||
| Design mass (kg) | 1655 | 1725 | 1765 | 1825 | 2460 | 2540 | 2610 | 2695 | 3090 | 3209 | 3280 | 3698 | 4050 | 4229 | 4336 | 4889 |
| Operating load (N) | 61000 | 66000 | 70000 | 74000 | 95000 | 103000 | 108000 | 114000 | 141000 | 154000 | 162000 | 173000 | 193000 | 203000 | 223000 | 243000 |
| Nominal diameter resin layer height item |
DN2000 | DN2200 | DN2500 | DN2800 | ||||||||||||
| 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | |
| JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | JNL | |
| 200·200A | 200·250A | 200·280A | 200·320A | 220·200A | 220·250A | 220·280A | 220·320A | 250·200A | 250·250A | 250·280A | 250·320A | 280·200A | 280·250A | 280·280A | 280·320A | |
| design capacity (t/h) | 125 | 150 | 195 | 245 | ||||||||||||
| Resin volume (m3) | 6.28 | 7.85 | 8.79 | 10.05 | 7.6 | 9.5 | 10.64 | 12.16 | 9.8 | 12.25 | 13.72 | 15.7 | 12.31 | 15.39 | 17.24 | 19.7 |
| compressed resin volume (m3) | 0.63 | 0.76 | 0.98 | 1.23 | ||||||||||||
| Design mass (kg) | 4510 | 4695 | 4814 | 4973 | 5840 | 6113 | 6277 | 6495 | 6865 | 7175 | 7361 | 7609 | 8320 | 9165 | 9500 | 9830 |
| Operating load (N) | 193000 | 271000 | 289400 | 313500 | 263000 | 286000 | 304000 | 321000 | 392000 | 432000 | 443000 | 449000 | 325000 | 447000 | 478000 | 482000 |
2. Technical parameters
The main technical parameters of porous plate and water cap floating bed ion exchanger are shown in table 19-2
Table 19-2 main technical parameters of porous plate and water cap floating bed ion exchanger
| Item | Data | Item | Data |
| Design pressure(MPa) | 0.6 | container form | Vertical |
| Design temperature(℃) | 50 | Welded joint coefficient | 0.85 |
| design flow rate(m/h) | 40 | material of the main body | Q235-B |
| Design capacity(t/h) | see table 19-1 | Resin layer height(mm) | see table 19-1 |
3. Equipment appearance and structural dimensions
The shape and structural dimensions of porous plate and water cap floating bed ion exchanger are shown in Fig. 19-1, table 19-3 and table 19-4

Table 19-3 main dimensions
| Nominal diameter Resin layer height Item |
DN1000 | DN1250 | DN1600 | DN1800 | DN2000 | DN2200 | DN2500 | DN2800 | |||||||||||||||||||||||||
| 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | 2000 | 2500 | 2800 | 3200 | ||
| H | 4286 | 4786 | 5086 | 5486 | 4539 | 5039 | 5339 | 5739 | 5285 | 5785 | 6085 | 6485 | 4842 | 5342 | 5642 | 6042 | 4942 | 5442 | 5742 | 6142 | 5081 | 5581 | 5881 | 6281 | 5335 | 5835 | 6135 | 6535 | 5489 | 5989 | 6289 | 6689 | |
| H1 | 3786 | 4286 | 4586 | 4986 | 4039 | 4539 | 4839 | 5239 | 4785 | 5285 | 5585 | 5985 | 4342 | 4842 | 5142 | 5542 | 4442 | 4942 | 5242 | 5642 | 4581 | 5081 | 5381 | 5781 | 4835 | 5335 | 5635 | 6035 | 4989 | 5489 | 5789 | 6189 | |
| H2 | 3092 | 3592 | 3892 | 4292 | 3269 | 3769 | 4069 | 4469 | 3601 | 4101 | 4401 | 4801 | 3372 | 3872 | 4172 | 4572 | 3422 | 3922 | 4222 | 4622 | 3474 | 3974 | 4274 | 4674 | 3651 | 4151 | 4451 | 4851 | 3728 | 4228 | 4528 | 4928 | |
| H3 | 819 | 988 | 1351 | 1122 | 1172 | 1222 | 1401 | 1478 | |||||||||||||||||||||||||
| H4 | 300 | 400 | 400 | 400 | 400 | 400 | 500 | 500 | |||||||||||||||||||||||||
| H5 | 445 | 560 | 580 | 595 | 595 | 640 | 730 | 730 | |||||||||||||||||||||||||
| H6 | 1000 | 1000 | 1000 | 1200 | 1200 | 1200 | 1300 | 1300 | |||||||||||||||||||||||||
| H7 | 1450 | 1450 | 1450 | 1750 | 1750 | 1750 | 1850 | 1850 | |||||||||||||||||||||||||
| N×M | 100×140 | 180×220 | 180×220 | 180×220 | 180×220 | 180×220 | 300×350 | 300×350 | |||||||||||||||||||||||||
| L1 | 754 | 896 | 1091 | 1208 | 1308 | 1445 | 1595 | 1747 | |||||||||||||||||||||||||
| L2 | 145 | 160 | 180 | 195 | 195 | 230 | 230 | 230 | |||||||||||||||||||||||||
| L3 | 248 | 313 | 333 | 398 | 398 | 433 | 433 | 433 | |||||||||||||||||||||||||
| L4 | 180 | 200 | 210 | 230 | 230 | 280 | 280 | 280 | |||||||||||||||||||||||||
| LA~LD | See table 19-4 | ||||||||||||||||||||||||||||||||
| ∮ | 985 | 1000 | 1450 | 1600 | 1800 | 1900 | 2000 | 2150 | |||||||||||||||||||||||||
| DN1 | 80 | 80 | 100 | 100 | 100 | 100 | 100 | 100 | |||||||||||||||||||||||||
| DN2 | 32 | 40 | 50 | 50 | 50 | 80 | 80 | 80 | |||||||||||||||||||||||||
| DN3 | 50 | 80 | 100 | 125 | 125 | 150 | 150 | 150 | |||||||||||||||||||||||||
| DN4 | 80 | 100 | 125 | 150 | 150 | 200 | 200 | 200 | |||||||||||||||||||||||||
| DN5 | 32 | 50 | 80 | 80 | 100 | 125 | 125 | 125 | |||||||||||||||||||||||||
| DN6 | 32 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | |||||||||||||||||||||||||
Table 19-4 LA ~ LD dimensions of porous plate and water cap floating bed ion exchanger
| Main parameter Manual or Pneumatic type Sanders pneumatic Nominal diameter |
LA | LB | LC | LD |
| DN1000 | 160 | 160 | 210 | 300 |
| 150 | 150 | 194 | 258 | |
| DN1250 | 180 | 210 | 300 | 350 |
| 163 | 194 | 258 | 309 | |
| DN1600 | 210 | 300 | 350 | 400 |
| 194 | 258 | 309 | 362 | |
| DN1800 | 210 | 300 | 400 | 460 |
| 194 | 258 | 362 | 412 | |
| DN2000 | 210 | 350 | 400 | 460 |
| 194 | 309 | 362 | 412 | |
| DN2200 | 300 | 400 | 460 | 570 |
| 258 | 362 | 412 | 529 | |
| DN2500 | 300 | 400 | 460 | 570 |
| 258 | 362 | 412 | 529 | |
| DN2800 | 300 | 400 | 460 | 570 |
| 258 | 362 | 412 | 529 |
Note: for manual rubber lined diaphragm valve, LC, LD, LE values are zero.
4. Ordering instructions
4.1. The regeneration liquid of the equipment is hydrochloric acid, sulfuric acid and sodium hydroxide.
4.2. The equipment is designed according to strong resin. If the user uses weak resin for operation, it must be noted when ordering.