Product Description

Condenser surface

 

1. Introduction

1.1. Purpose

Surface condenser is a power plant steam power cycle device, through the establishment and maintenance of a certain vacuum at the exhaust side of the steam turbine, receives the steam turbine exhaust, condenses into clean condensate, and returns to the boiler for circulation. This type of condenser has been widely used in modern power plants.

1.2. Model meaning

N-**

N -- condenser number finding

**--------Cooling area (m2)

1.3. Structural features

1.3.1. Structural form:

1.3.1.1. The structure of surface condenser. According to the flow direction of steam flow, surface condenser can be divided into four types: downward type, upward type, lateral type and centripetal type (see Figure 24-1). Steam flow side type and centripetal type are widely used in modern large condenser.

1.3.1.2. Arrangement of surface condenser. The arrangement of condenser relative to steam turbine mainly depends on the design of low pressure exhaust hood and turbine foundation, and also related to the design of turbine room. Figure 24-2 shows several arrangement schemes of condenser relative to steam turbine, among which the longitudinal and transverse arrangement schemes of condenser under the steam turbine are most widely used.

1.3.2. Structure description. The cooling water is continuously fed into the cooling pipe of the surface condenser by the circulating water pump. The exhaust steam of the steam turbine is introduced into the condenser and condensed into water outside the cooling pipe. The heat released during steam condensation is taken away by the cooling water; Condensate is extracted from the condenser hot well by condensate pump as boiler feed water. The non condensable gas in the condenser is removed by the air extraction equipment. The condenser maintains the required vacuum and the equipment operates normally.

1.3.3. Description of important components. The surface condenser is mainly composed of neck, shell, water chamber, hot well exhaust pipe, etc. The whole condenser is supported on the reinforced concrete foundation by using spring support seat or rigid support seat, and is connected with the exhaust port of low pressure cylinder through exhaust nozzle (if it is rigid support seat, expansion joint is also required).

Surface condenser can be divided into single shell condenser and double shell condenser, as shown in Figure 24-3 and figure 24-4

1.3.3.1. The connection neck of the condenser connects the steam outlet of the steam turbine with the shell of the condenser to receive, organize and distribute steam. The first or second stage low-pressure heater and the last stage temperature and pressure reducing device of steam turbine bypass are arranged in the connection neck of large-scale condenser, and the exhaust pipe of feed pump turbine, the exhaust pipe of bypass system, several stages of steam extraction pipe of steam turbine, steam seal and steam supply pipe of low-pressure cylinder are set. A water curtain protection device is also set in the connection neck to control the exhaust steam temperature of the last stage temperature and pressure reducing device of the bypass system below 80 ℃, so that the bypass steam can be further cooled after entering the connection neck, and it can not reverse flow into the low-pressure cylinder to ensure the safety of the low-pressure cylinder and the last stage blade.

The joint neck is generally of low carbon steel welding structure, with steel pipe cross support inside. It must be able to bear an external pressure of 0.1MPa under vacuum condition with sufficient strength and rigidity. Two connecting necks of single back pressure double shell condenser are connected by connecting pipe to ensure the balance of pressure difference in operation.

1.3.3.2. Shell. The shell is the main part of the condenser, which is welded with carbon steel plate and reinforced by supporting clapboard or steel pipe. The modern condenser generally adopts rectangular shell.

The tube bundle is arranged in the shell, and a certain width of steam channel is set around the tube bundle to achieve reasonable steam flow rate and ensure the excellent performance of the condenser. Both ends of the shell are fixed on the shell by welding. Depending on the quality of cooling water, carbon steel plate, aluminum bronze plate, nickel white copper plate, stainless steel plate, stainless steel carbon steel composite plate, titanium plate and titanium steel composite plate can be selected respectively. The cooling tubes of tube bundle are made of copper tube, stainless steel tube and titanium tube. In order to improve the corrosion resistance of cooling pipes, stainless steel tubes and titanium tubes are often used in large condensers. A certain number of intermediate diaphragms are set between the front and rear tubesheets to support the cooling tubes, so as to ensure the cooling tubes have enough rigidity and avoid resonance, so as to prevent the pipes from being damaged due to vibration during operation.

A condensate water collecting tank is arranged under the tube bundle, also known as a hot well. The hot well can be made into a separate type, that is, an independent hot well is arranged under the shell, or it can be integrated with the shell, and the lower part of the shell is the hot well. The latter is widely used in large condensers. The pad well should have a certain effective volume and deaeration measures. The condensate is led out through the condensate outlet pipe at the bottom of the hot well.

The shells of the double shell condenser are connected by pipes, which makes the condensate flow from one shell to the bottom of the other, and finally flows out of the body.

1.3.3.3. Water chamber. The water chamber of the condenser is the component to guide the cooling water into and out of the cooling pipe, and it should have sufficient strength and rigidity. The shape and structure of the water chamber mainly depends on the shape of the tube bundle on the tubesheet, the number of cooling water passes, the design water velocity and pressure in the water chamber, and the size and position of the cooling water connecting pipe on the water chamber. There are rectangular water chamber, semi cylindrical water chamber, wedge-shaped water chamber, spherical water chamber and semi elliptical cylindrical water chamber with flat side plate. The water chamber with rubber ball cleaning device should be designed to avoid vortex area and dead angle to prevent rubber ball from accumulating. Each water chamber shall be provided with 2 manholes for cleaning and maintenance. The water chamber is usually welded with carbon steel plate. When seawater is used as cooling water, rubber lining or epoxy resin coating are generally used to avoid seawater corrosion.

In addition, considering the combination of different materials in the cooling water system such as water chamber, tube sheet, cooling pipe and cooling water connecting pipe, electrochemical corrosion often occurs, and cathodic protection is often set in the water chamber. Cathodic protection is made of materials with lower potential than various materials in water chamber, and sacrificial anode is used to achieve the purpose of corrosion protection. At present, zinc or manganese are widely used.

1.3.4. Description of important characteristics:

1.3.4.1. Supervision in operation. The advantages and disadvantages of condenser operation performance are mainly reflected in condenser pressure (vacuum), condensate subcooling degree and condensate quality. During operation, the pressure of condenser, steam temperature entering condenser, condensate temperature, inlet and outlet temperature and pressure of cooling water, oxygen content and salt content of condensate, temperature of extracted steam gas mixture and inlet steam (or condensate) shall be supervised.

1.3.4.2. Back flushing of condenser. The impurities in cooling water will lead to blockage of cooling pipe on tube sheet, decrease of cooling water flow and deterioration of vacuum of condenser. In serious cases, it will cause siphon damage of cooling water outlet pipe and interruption of cooling water supply, and forced shutdown. The backwash system can be used in the once through water supply system.

1.3.5. Other types of condensers:

1.3.5.1. Multi pressure condenser. The multi pressure condenser is to separate the steam chambers of the condenser into two or more parts which are not connected with each other. The exhaust steam of each steam outlet of the steam turbine is discharged into the respective steam chambers respectively, and the cooling water is connected in series through the tube bundles of each steam chamber. Because the inlet temperature of cooling water in each steam chamber is different, the pressure of each steam chamber is different, so each low pressure cylinder of steam turbine operates under different exhaust pressure.

The advantages of multi pressure condenser are as follows:  ① the average condenser pressure of multi pressure condenser is lower than that of single pressure condenser with the same cooling area and cooling water flow rate, so the unit efficiency and output can be improved; ② When the condenser pressure is the same, the multi pressure condenser can reduce the cooling area and / or cooling water volume, thus reducing the investment and / or operating costs; ③ Because the multi pressure condenser introduces the condensate from the low pressure section into the high pressure section and heats it to the saturation temperature corresponding to the high pressure section, the increase of the condensate outlet temperature reduces the steam extraction capacity of the steam turbine and increases the output of the unit.

1.3.5.2. Air cooled condenser. Air cooled condensing equipment takes air as the basic cooling medium, basically does not consume cooling water, so it can be used in water shortage areas. The key of air-cooled condenser is air-cooled radiator (air-cooled Island). Air cooled radiator is finned tube heat exchange equipment. It uses ambient air as cold source to condense or cool exhaust steam of steam turbine in power plant, thus completing steam power cycle of power plant.

The air-cooled power station can be used as a supplement to the water-cooled power station, which makes the site selection of the power station more flexible and more reasonable.

 

2. Main technical parameters and product appearance

2.1. Main technical parameters (see table 24-1)

Table 24-1 main technical parameters of surface condenser

Model Type Cooling area Cooling water volume Pressure Cooling water inlet temperature Pipe material Weigh Remark
(m2) (M3/h) (KPa) (℃) (t)
N-18000 Single back pressure, single shell, split type, double flow 18000 35460 4.9 20 Stainless steel pipe 345 Suit 300MW unit
N-34000 Single back pressure, double shell, split type, double flow 34000 71092 4.9 20 Titanium tube 600 Suit 600MW subcritical units
N-34000 Double back pressure, double shell, split type, single process 34000 69588 4.9 20 Titanium tube 660 Suit 600MW subcritical, supercritical,ultra supercritical units
N-55000 Double back pressure, double shell, split type, single process 55000 103817 5.3 21 Stainless steel pipe 1183 Suit 1000MW Ultra supercritical unit 

 

2.2. Product appearance (see Figure 24-3, figure 24-4 and table 24-2)

Table 24-2 overall dimensions of condenser products

Model Type L W H Remark
N-18000 Single back pressure, single shell, split type, double flow 15454 12900 11667 Suit 300MW unit
N-34000 Single back pressure, double shell, split type, double flow 18410 16730 13510 Suit 600MW subcritical units
N-34000 Double back pressure, double shell, split type, single process 19170 16730 13510 Suit 600MW subcritical, supercritical,ultra supercritical units
N-55000 Double back pressure, double shell, split type, single process 23710 17850 12885

Suit 1000MW Ultra supercritical unit 

 

3. Selection method

The technical data provided by the equipment purchaser are as follows.

3.1. Project overview.

3.2. Design and operating conditions:

3.2.1. Main original data (environmental conditions) of the project.

3.2.2. System and related equipment overview.

3.2.3. Equipment installation and operation conditions.

3.3. Technical conditions:

3.3.1. Design conditions.

3.3.2. Equipment performance requirements.

3.3.3. Equipment manufacturing requirements.

3.3.4. Equipment material requirements.

3.3.5. Instrumentation and control requirements.

3.3.6. Standards adopted.

3.3.7 equipment performance guarantee value.

3.3.8 equipment test and requirements.

3.3.9. Equipment painting, packaging and transportation requirements.

 

4. Scope of supply

4.1. Condenser body, including support seat, expansion joint, pipeline and connecting pipe in the system.

4.2. Bypass last stage temperature and pressure reducing device

4.3. Drain flash tank.

4.4. Matching valves and accessories.

4.5. Instrument control elements,

4.6. Spare parts.

4.7. Special tools.

Installation and maintenance data.

Items 4.4 and 4.5. Can be manufactured, purchased and configured by the supplier or purchased or configured by itself.