Malta Porous plate & water cap type counter current regeneration ion exchanger

Product Description

Porous plate and water cap counter current regeneration ion exchanger

 

1. Introduction

1.1. Purpose

The equipment is used for water purification. During operation and regeneration, the direction of liquid flow through the exchanger is opposite. The regeneration degree is high, the consumption of regenerant is low, and the quality of effluent is guaranteed. However, the equipment and the regeneration operation are complicated, including three types of gas top pressure, water top pressure and no top pressure.

1.2. Model meaning

                  J NL 100•125 B

                  J-----------Ion exchange

                  NL -------- counter current regeneration and lining

                  100 -------- equipment diameter (mm)

                   125 -------- resin layer height (mm)

                    B -------- porous plate, water cap type

1.3. Structural features

1.3.1. The water inlet device is dome shaped porous plate

1.3.2. The regeneration liquid device in the middle is in the form of mother pipe and branch pipe.

1.3.3. The water outlet device is in the form of porous plate and water cap.

1.3.4. The equipment is equipped with local sampling device and water inlet and outlet pressure gauges.

1.3.5. The pressure rating of all interface flanges is PN1.0MPa.

1.3.6. The equipment can be equipped with manual rubber lined diaphragm valve and pneumatic rubber lined diaphragm valve.

1.3.7. The equipment is lined with 1751 semi-rigid adhesive for anti-corrosion.

1.3.8 when the equipment diameter DN ≤ 1250, the large flange structure is adopted at the porous plate.

1.4. Product series

See table 17-1 for the products of porous plate and water cap counter current regeneration ion exchanger

Table 17-1 product series of parallel flow regeneration ion exchanger with porous plate and water cap

Nominal diameter

resin layer height

item
DN1000 DN1250 DN1600 DN1800 DN2000
1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500
JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL
100·160B 100·200B 100·250B 125·160B 125·200B 125·250B 160·160B 160·200B 160·250B 180·160B 180·200B 180·250B 200·125B 200·200B 200·250B
design capacity (t/h) 15 25 40 50 65
Resin volume  (m3) 1.26 1.57 1.96 1.96 2.45 3.07 3.2 4.02 5.02 4.07 5.1 6.36 5.02 6.28 7.85
compressed resin volume (m3) 0.16 0.25 0.4 0.51 0.63
Design mass (kg) 1691 1796 1936 2340 2489 2686 2870 3063 3322 3794 4073 4442 4268 4576 4982
Operating load (N) 45200 51620 57820 68630 78470 90810 111450 127090 146790 137120 157190 182500 169640 196030 226790
                               
Nominal diameter

resin layer height

item
DN2200 DN2500 DN2800 DN3000 DN3200
1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500
JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL JNL
220·125B 220·200B 220·250B 250·160B 250·200B 250·250B 280·160B 280·200B 280·250B 300·160B 300·200B 300·250B 320·160B 300·200B 300·250B
design capacity (t/h) 75 100 125 140 160
Resin volume  (m3) 6.08 7.6 9.5 7.85 9.82 12.27 9.85 12.31 15.39 11.3 14.13 17.66 12.86 16.08 20.1
compressed resin volume (m3) 0.76 0.98 1.23 1.41 1.61
Design mass (kg) 5393 5807 6345 7100 7570 8182 8771 9391 10191 10025 10699 11574 10841 11557 12485
Operating load (N) 242680 274660 312330 273600 311700 359460 348180 395920 456620 404150 458890 527720 459440 521240 598830

 

2. Technical parameters

2.1. Main technical parameters

The main technical parameters of porous plate and water cap counter current regeneration ion exchanger are shown in table 17-2

Table 17-2 main technical parameters of porous plate and water cap counter current regeneration ion exchanger

Item Data Item Data
Design pressure(MPa) 0.6 container form Vertical
Design temperature(℃) 50 Welded joint coefficient 0.85
design flow rate(m/h) 20 material of the main body Q235-B
Design capacity(t/h) see table 17-1 Resin layer height(mm) see table 17-1

2.2. Special parameters

The turbidity of influent water should be less than 2mg / L

 

3. Equipment appearance and structural dimensions

See Fig. 17-1, table 17-3 and table 17-4 for the outline and structural dimensions of multi hole type and water cap type forward flow ion exchanger

Table 17-3 

Nominal diameter

Resin layer height

Item
DN1000 DN1250 DN1600 DN1800 DN2000 DN2200 DN2500 DN2800 DN3000 DN3200
1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500 1600 2000 2500
H 4456 5136 5986 4696 5376 6226 5167 5847 6697 5025 5705 6697 5025 5705 6555 5244 5924 6774 5496 6176 7026 5650 6330 7180 5787 6467 7317 5887 6567 7417
H0 1800 1800 1800 1800 1800 1800 1800 1800 1800 1800
H1 129 229 214 194 194 194 229 229 194 194
H2 422 522 537 557 557 557 622 622 657 657
H3 715 915 860 920 920 920 1015 1015 1120 1120
H4 1450 1450 1450 1450 1450 1450 1600 1600 1600 1600
∮ 985 1000 1450 1600 1800 1900 2000 2150 2275 2400
L1 145 145 160 180 180 180 195 195 230 230
L2 248 248 313 333 333 333 398 398 433 433
L3 240 240 290 290 290 320 320 360 360 360
L4 729 856 1056 1158 1258 1375 1525 1697 1797 1897
L5 754 881 1071 1193 1293 1395 1560 1712 1847 1947
L6 180 180 200 220 220 220 280 280 280 280
L7 623 757 933 1033 1136 1240 1380 1536 1638 1740
LA~LE see table 17-4
N×M 100×14 180×220 180×220 180×220 180×220 180×220 300×350 300×350 300×350 300×350
DN1 80 80 100 125 125 125 150 150 200 200
DN2 50 50 80 80 80 100 100 125 125 125
DN3 32 32 40 40 40 40 40 50 50 50
∮ 985 1000 1450 1600 1800 1900 2000 2150 2275 2400

 

Table 17-4 dimensions of LA ~ LD for parallel flow regeneration ion exchanger with porous plate and water cap

Main parameter
Manual or Pneumatic type
Sanders pneumatic
Nominal diameter
LA LB LC LD
DN1000 300 210 150 250
258 194
DN1250 300 210 150 250
258 194
DN1600 350 300 — 250
309 258
DN1800 400 300 — 200
362 258
DN2000 400 300 — 200
362 258
DN2200 400 350 150 320
362 309
DN2500 460 350 — 280
412 309
DN2800 460 400 — 280
412 362
DN3000 570 400 150 420
529 362
DN3200 570 400 150 420
529 362

Note: for manual rubber lined diaphragm valve, LC, LD, LE values are zero.

 

4. Ordering instructions

The regeneration liquid of the equipment is hydrochloric acid, sulfuric acid and sodium hydroxide. When the flow rate of regeneration liquid is 10m / h, it should be indicated when ordering. If users use no top pressure regeneration, please indicate when ordering.