PRODUCTS CENTER
Malta BDGXG new high efficiency fiber filter
Category:
Product Description
BDGXG new high efficiency fiber filter
1. Introduction
BDGXG new type high efficiency fiber filter is the second generation fiber filter device developed by Jiangsu Bada science and technology company. It is a major technical improvement and innovation based on a large number of operation experience of the first generation filter.
The equipment is composed of fixed porous plate, movable orifice plate and fiber. Extrusion device is divided into three types: air bag, manpower and machinery. The movable orifice plate can move up and down, so that the pores of the filter material along the water flow direction will gradually decrease, and the fiber density will increase. The filtration process includes vertical deep filtration and horizontal deep filtration, which can effectively improve the filtering accuracy and filtering speed. During cleaning, the fiber is loose, and the method of gas hydrate washing is adopted. During the process of bubble gathering and dispersing and hydraulic flushing, the fiber is in the state of continuous shaking. Under the action of downward hydraulic pressure and rising bubble, the filter material is regenerated.
1.1. Main features
1.1.1. The structure is simple and the operation is easy. Bdgxg new high efficiency fiber filter is divided into type A and type B. The main structure and operation mechanism of type A and type B are basically the same, but the direction of filtration is opposite. Type A is upward filtration and type B is downward filtration, which are suitable for different needs. Generally, type A is suitable for pressure type, and type B is suitable for gravity type. The equipment has no wearing parts and can operate for more than 10 years without replacing the main parts. The operation method is similar to that of granular filter.
1.1.2. The filtration precision is high. After coagulation treatment, the suspended solids can be removed more than 90%, and the impurities such as bacteria, virus and macromolecular organic matter can be significantly removed.
1.1.3. The filtering speed is fast. It is 3-5 times of that of the traditional filter, and the maximum is 50 m / h.
1.1.4. It is 2-4 times of the traditional filter.
1.1.5. For the same amount of water, the new type of high efficiency fiber filter occupies only 1 / 5 ~ 1 / 3 of the traditional filter, which greatly saves the investment in infrastructure construction.
1.1.6. The cost of ton water is low. It is 1 / 2 ~ 2 / 3 of the traditional filter
1.1.7. Low water consumption. It is only 1% - 3% of the water produced. Generally, raw water can be used for backwashing.
1.1.8. It is not necessary to replace the filter element. It can be easily cleaned with air and water to recover the filtration performance.
1.2. Purpose
Bdgxg high efficiency fiber speeder can be widely used in industrial water supply system, circulating cooling water side filtration, heat supply network with water filtration, advanced sewage treatment system, domestic drinking water, bath water circulation treatment, etc. Bdgxg new type high efficiency fiber filter has been widely used in electric power, petroleum, chemical industry, coal, metallurgy, electronics, papermaking, medical treatment, tap water, beverage, urban sewage and other industries since its inception. It has hundreds of operating experience of products, which has created observable economic and social benefits for the majority of users.
2. Sketch of new high efficiency fiber filter
The schematic diagram of the new high efficiency fiber filter is shown in Fig. 3-1.

3. Nozzle size
See table 3-1 for nozzle size of new high efficiency fiber filter
Table 3-1 nozzle size of new high efficiency fiber filter
| Model Nozzle size Item |
BDGXG-100 | BDGXG-120 | BDGXG-150 | BDGXG-180 | BDGXG-200 | BDGXG-250 | BDGXG-280 | BDGXG-300 |
| Raw water inlet A | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Clean water outlet B | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Backwash inlet C | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Backwash outlet D | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Drain outlet E | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Compressed air inlet F | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Exhaust port G | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 200 |
| Adding alkali H | 50 | 50 | 50 | 65 | 65 | 80 | 80 | 80 |
4. Technical characteristics
See table 3-2 for technical characteristics of new type high efficiency fiber filter
Table 3-2 technical characteristics of new high efficiency fiber filter
| Nominal Diameter Model Item |
DN1000 | DN1200 | DN1500 | DN1800 | DN2000 | DN2500 | DN2800 | DN3000 | |
| BDGXG-100 | BDGXG-120 | BDGXG-150 | BDGXG-180 | BDGXG-200 | BDGXG-250 | BDGXG-280 | BDGXG-300 | ||
| Drainage area(m2) | 0.785 | 1.13 | 1.77 | 2.54 | 3.14 | 4.9 | 6.15 | 7.06 | |
| Design filtration capacity(m3/h) | 24 | 34 | 53 | 76 | 94 | 147 | 184 | 210 | |
| Equipment net weight(kg) | 1620 | 1850 | 2530 | 3250 | 4690 | 8260 | 9650 | 10640 | |
| Equipment running weight(kg) | 3450 | 3990 | 8100 | 9210 | 15600 | 23600 | 29800 | 34300 | |
| Maximum working pressure(MPa) | 0.6 | ||||||||
| Pressure difference between inlet and outlet (MPa) | <0.2 | ||||||||
| Sewage interception capacity(kg/ m3) | 10~15 | ||||||||
| Filtration rate(m/h) | 20~40 | ||||||||
| Filtration period (h) | >8 | ||||||||
| Water quality before filtration | Turbidity(MPa) | 20~50 | Water quality before filtration | Turbidity(NTV) | ≤5 | ||||
| Turbidity(MPa) | ≤20 | Turbidity(NTV) | ≤1 | ||||||
| cleaning water flow | Wash up,3~5 | ||||||||
| 〔L(m2·s〕 | Wash down,6~10 | ||||||||
| Cleaning parameter | Cleaning water pressure | 0.05~0.1 | |||||||
| (MPa) | |||||||||
| Cleaning air pressure | 0.05~0.06 | ||||||||
| (MPa) | |||||||||
| Cleaning air intensity | 40~60 | ||||||||
| 〔L(m2·s〕 | |||||||||
| cleaning time(min) | 20~60 | ||||||||
5. Structure size
See table 3-3 for the structure and size of the new high efficiency fiber filter
Table 3-3 structural dimensions of new high efficiency fiber filter
| Nominal Diameter Model Item |
DN1000 | DN1200 | DN1500 | DN1800 | DN2000 | DN2500 | DN2800 | DN3000 |
| BDGXG-100 | BDGXG-120 | BDGXG-150 | BDGXG-180 | BDGXG-200 | BDGXG-250 | BDGXG-280 | BDGXG-300 | |
| H | 2950 | 3050 | 3500 | 3700 | 4000 | 4300 | 4450 | 5110 |
| H1 | 600 | 600 | 800 | 1000 | 1200 | 1300 | 1500 | 1500 |
| H2 | 150 | 150 | 150 | 200 | 200 | 229 | 229 | 229 |
| H3 | 400 | 400 | 400 | 500 | 500 | 600 | 890 | 890 |
| H4 | 200 | 200 | 250 | 350 | 350 | 400 | 600 | 610 |
| L | 700 | 800 | 1000 | 1200 | 1300 | 1500 | 1700 | 1800 |
| L1 | 350 | 400 | 500 | 600 | 600 | 850 | 1000 | 1200 |
| L2 | 350 | 400 | 500 | 600 | 600 | 850 | 1000 | 1200 |
| L3 | 350 | 400 | 500 | 600 | 600 | 850 | 1000 | 1200 |
| R | 350 | 450 | 500 | 700 | 850 | 1150 | 1150 | 1200 |
| a×b | 150×200 | 150×200 | 150×200 | 200×250 | 200×250 | 250×300 | 300×350 | 300×350 |
6. Equipment environment and installation
6.1. The temperature of water shall not be less than 1 ° C and not higher than 100 ° C.
6.2. The perpendicularity tolerance of the equipment central axis to the installation horizontal plane shall not be greater than 1:1000.
6.3. Before installation, the matching valves should be carefully checked to prevent internal leakage.
6.4 check valves shall be connected in series in the pipeline between Roots blower and filter to prevent water from flowing into the machine.
7. Commissioning and operation of equipment
7.1. Check whether the supporting equipment, roots blower, valve, water pump and pipeline are normal.
7.2. The equipment should be backwashed before putting into operation. Open the valve according to the backwashing procedure in the equipment operation procedure sheet. Keep the backwashing water for 30-60 min. At this time, there will be a lot of bubbles in the anti washing water. This is due to the large amount of air adsorbed on the surface of the fiber filter. After about 0.5h, the foam will disappear. It can be put into operation at this time.
(3) After the equipment is put into operation, the filter material has an activation process. After 8-12 hours, the filtering accuracy will be gradually improved.
8. Equipment cleaning
8.1. The scrubbing air shall be free of oil and other impurities.
8.2. After the equipment has been running for a period of time, if the effluent quality drops or the filtration resistance is too large (pressure difference is greater than 0.08mpa), it should be cleaned. The user can determine according to the specific situation.
8.3. The main cleaning method of the equipment is backwashing, and the backwashing method is steam water combined backwashing. According to the specific use conditions, the duration of backwashing will be different, generally 20-60min. The general principle is to observe the backwashing effluent. When the water flow gradually becomes clear or nearly clear, the backwashing process can be completed.
8.4. The equipment can obtain good cleaning effect after backwashing, which can meet the operation requirements in general. When there is a special need for the cleanliness of the filter layer, it can be scrubbed after backwashing. After backwashing, the equipment should be kept full of water (the filter layer should be kept loose).
9. Precautions
9.1. Before the equipment leaves the factory, the filter layer of the equipment has been adjusted, and the user generally does not need to adjust it by himself.
9.2. In the long-term operation of the equipment, a large amount of organic matter, oil, etc. may be accumulated on the surface of the fiber filter material under specific conditions, and microorganisms may even grow, resulting in a significant increase in the running resistance of the equipment, the filtering accuracy is reduced, and the output is reduced. The equipment can be soaked in 2% NaOH solution for 24h
9.3. The equipment shall be stored with full water during shutdown.
The maximum working pressure of the equipment shall not be greater than 0.6MPa
: next page