Porous plate & water cap type downstream regeneration ion exchanger

key word:Heat exchange element


Product description

Porous plate, water cap type downstream regeneration ion exchanger

 

1. Introduction

1.1. Purpose

The equipment is used for water purification. The direction of liquid flow through the exchanger is consistent during operation and regeneration, and the equipment is easy to operate.

1.2. Model meaning

                     J SL 100•125 B

                    J ------ ion exchange

                    SL -------- downstream regeneration and lining

                    100 --- equipment diameter (mm)

                    125 -------- resin layer height (mm)

                     B---------Porous plate, water cap type

1.3. Structural features

The water inlet device is in the form of domed porous plate.

The inlet of regeneration liquid device is in the form of mother pipe and branch pipe.

The water outlet device is porous.

The equipment is equipped with local sampling device and water inlet and outlet pressure gauges.

The pressure rating of all interface flanges is PN1.0MPa

The equipment can be equipped with manual rubber lined diaphragm valve and pneumatic rubber lined diaphragm valve.

The equipment is lined with 1751 semi-rigid adhesive for anti-corrosion.

When the equipment diameter DN ≤ 1250, large flange structure is adopted.

1.4. Product series

See table 15-1 for the product series of porous plate and water cap type downstream regeneration ion exchanger

Nominal diameter

resin layer height

item
DN1000 DN1250 DN1600 DN1800 DN2000
1250 1600 2000 1250 1600 2000 1250 1600 2000 1250 1600 2000 1250 1600 2000
JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL
100·125B 100·160B 100·200B 125·125B 125·160B 125·200B 160·125B 160·160B 160·200B 180·125B 180·160B 180·200B 200·125B 200·160B 200·200B
design capacity (t/h) 15 25 40 50 65
Resin volume  (m3) 0.98 1.26 1.57 1.54 1.96 2.45 2.51 3.2 4.02 3.2 4.07 5.1 3.9 5.02 6.28
Design mass (kg) 1463 1550 1594 2036 2158 2298 2413 2571 2574 3253 3481 3742 3718 3970 4259
Operating load (N) 35750 40970 46460 54320 62400 71650 88160 100960 115680 108300 124830 143700 137180 157350 180210
                               
Nominal diameter

resin layer height

item
DN2200 DN2500 DN2800 DN3000 DN3200        
1250 1600 2000 1600 2000 1600 2000 1600 2000 1600 2000        
JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL JSL        
220·125B 220·160B 220·200B 250·160B 250·200B 280·160B 280·200B 300·160B 300·200B 320·160B 32·200B        
design capacity (t/h) 75 100 125 140 160        
Resin volume  (m3) 4.75 6.08 7.6 7.85 9.82 9.85 12.31 11.3 14.13 12.86 16.08        
Design mass (kg) 4659 5000 5394 6714 7157 7801 8384 9156 9797 9896 10569        
Operating load (N) 164780 189460 217720 252080 287910 316410 361640 370020 421610 421050 479210        

 

2. Technical parameters

2.1. Main technical parameters

See table 15-2 for the main technical parameters of porous plate and water cap type downstream regeneration ion exchanger

Table 15-2 main technical parameters of parallel flow regeneration ion exchanger with porous plate and water cap

Item Data Item Data
Design pressureMPa 0.6 container form Vertical
Design temperature(℃) 50 Welded joint coefficient 0.85
design flow ratem/h 20 material of the main body Q235-B
Design capacityt/h see table 15-1 Resin layer heightmm see table 15-1

2.2. Special parameters

The consumption of regenerant is large, and the turbidity of influent is required to be less than 5mg / L

 

3. Equipment appearance and structural dimensions

See Fig. 15-1, table 15-3 and table 15-4 for the outline and structural dimensions of the downstream regeneration ion exchanger

Table 15-3 outline dimensions of the exchanger

Nominal diameter

Resin layer height

Item
DN1000 DN1250 DN1600 DN1800 DN2000 DN2200 DN2500 DN2800 DN3000 DN3200
1250 1600 2000 1250 1600 1250 1250 1600 1600 1600 2000 2000 2000 1600 2000 1600 2000 2000 1250 1600 2000 1250 1600 2000 1600 2000
H 3979 4539 5179 4149 4709 5349 4246 4806 5446 4433 4993 5633 4483 5403 5683 4550 5110 5750 5285 5925 5462 6102 5547 6187 5597 6237
H1 1235 1335 1380 1440 1440 1485 1585 1585 1690 1690
H2 738 838 883 943 943 988 1088 1088 1193 1193
H3 445 545 560 580 580 595 695 695 730 730
H4 152 252 237 217 217 202 302 302 267 267
H5 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
985 1000 1450 1600 1800 1900 2000 2150 2275 2400
L1 754 881 1071 1193 1293 1410 1560 1712 1874 1947
L2 729 856 1056 1158 1258 1360 1525 1677 1797 1897
L3 623 757 918 1025 1128 1233 1380 1536 1637 1740
L4 145 145 160 180 180 195 195 195 230 230
L5 251 251 316 336 336 401 401 401 436 436
L6 180 180 250 250 250 250 280 280 280 280
LALE see table 15-4
N×M 100×140 180×220 180×220 180×220 180×220 180×220 300×350 300×350 300×350 300×350
DN1 80 80 100 125 125 150 150 150 200 200
DN2 50 50 80 100 100 125 125 125 150 150
DN3 50 50 80 80 80 80 100 100 125 125
DN4 32 32 32 40 40 40 40 40 40 40
980 1000 1450 1600 1800 1900 2000 2150 2275 2400

 

Table 15-4 dimensions of main exchanger LA ~ lE

Main parameter
Manual or Pneumatic type
Sanders pneumatic
Nominal diameter
LA LB LC LD LE
DN1000 300 210 200
258 194
DN1250 300 210 200
258 194
DN1600 350 300 250
309 258
DN1800 400 350 280
362 309
DN2000 400 350 280
362 309
DN2200 460 400 350
412 362
DN2500 460 400 350
412 362
DN2800 460 400 350
412 362
DN3000 570 460 140 430
529 412
DN3200 570 460 140 430
529 412

Note: for manual rubber lined diaphragm valve, LC, LD, LE values are zero.

 

4. Ordering instructions

The regeneration liquid of the equipment is hydrochloric acid, sulfuric acid and sodium hydroxide. When the flow rate of regeneration liquid is more than 10m / h, it should be indicated when ordering.