2SA8 series multi rotary electric actuator
key word:Heat exchange element
Category:
Product description
2SA8 series multi rotary electric actuator
1. Introduction
1.1. Purpose
2SA8 series multi rotary electric actuator can output multi rotary motion, which is used to control gate valve, globe valve and diaphragm valve.
1.2. Model meaning
Code Position 5 6 7 8 9 10 11 12 13 14 15 16
2SA8 ** ## $$ - @@ && ** ※※ §§ -¢¢ ☆☆ □□ ^^
Code of 2SA8 --- 2SA8 series multi rotary electric actuator
**---------- Actuator series (Code position 5)
##------------Frame number and torque grading (Code position 6)
$$----------Frame number and torque grading (Code position 7)
@@--- output connection form (Code position 8)
&&------------------Output shaft speed (Code position 9)
**------------------ Power supply (Code position 10)
※※------------- Control module selection (Code position 11)
§§---------Protection sleeve of valve stem (Code position 12)
¢¢------ PID control module (Code position 13)
☆☆-------Bus communication (Code position 14)
□□---------Spare code (Code position 15)
^^---------Spare code (Code position 16)
1.2.1. Selection of actuator series (code position 5)
0: S series, switch type, 2SA80 series electric actuator, used in open-loop control system, motor standard is S2, 15min (short time intermittent working system);
5: R series, regulation type, 2SA85 series electric actuator, used in closed-loop control system, also the motor system is S4 or S5 (intermittent working system), the minimum load sustained rate is 10%, the maximum working times is 1200 times / h.
1.2.2. See table 61-1 for frame number and torque classification (code position 6 and 7).
Table 61-1 frame number and torque classification (code position 6 and 7)
| Code position 6, 7 | Output control torque range ((N·m) |
Flange No. | |
| (According to GB 12222) | |||
| 2SA80 | 2SA85 | ||
| 10 | 10~30 | 10~20 | F07 |
| 11 | 10~30 | 10~20 | F10 |
| 12 | 20~60 | 20~40 | F10 |
| 20 | 50~150 | 50~100 | F10 |
| 21 | 50~150 | 50~100 | F14 |
| 22 | 100~300 | 100~200 | F14 |
| 30 | 200~600 | 200~400 | F14 |
| 31 | 200~600 | 200~400 | F16 |
| 32 | 400~1200 | 400~800 | F16 |
| 40 | 800~2500 | 800~1600 | F25 |
| 41 | 800~2500 | 800~1600 | F30 |
| 50 | 1600~5000 | — | F30 |
| 51 | 1600~5000 | F35 | |
| 60 | 3200~10000 | F35 | |
| 61 | 3200~10000 | F40 | |
1.2.3. See table 61-2 and table 61-3 for output connection type and size
Table 61-2 output connection form (code position 8)
| Code position 8 | Connection standard | Output connection form | Remark | |||||
| A | GB 12222 (ISO 5210) |
It can transmit torque and bear thrust | See table 61-3 | |||||
| B | Torque transfer only (for rising stem valves) | |||||||
| C | Torque transfer only (for Non rising stem valves) | |||||||
| JB2920 | 8.1 | 8.2 | 8.3 | 8.4 | 8.5 | 8.6 | Appendix 1 and 2 | |
| D | 1 | 1 | 2 | 4 | 5 | 7 | ||
| E | 2 | 2(Ⅰ) | 3 | 5 | 7 | 8 | ||
| F | 2 | 4 | 7 | 8 | 9 | |||
| G | 3 | 5 | 10 | |||||
| H | Special connection form | |||||||
Appendix 1
| Code position 6, 7 | Output control torque range (N.m) | Flange number (according to GB 12222) |
| 10 | 15~20 | F07 |
| 11 | 15~20 | F10 |
| 12 | 30~40 | F10 |
| 20 | 60~80 | F10 |
| 21 | 60~80 | F14 |
| 22 | 125~175 | F14 |
| 30 | 250~350 | F14 |
| 31 | 250~350 | F16 |
| 32 | 500~700 | F16 |
| 40 | 1000~1400 | F25 |
| 41 | 1000~1400 | F30 |
| 42 | 2000~2800 | F30 |
Appendix 2
| Flange No. | 1 | 2 | 2(Ⅰ) | 3 | 4 | 5 | 7 | 8 | 9 | 10 |
| D | 115 | 145 | 115 | 185 | 225 | 275 | 330 | 380 | 430 | 510 |
| D1 | 95 | 120 | 95 | 160 | 195 | 235 | 285 | 340 | 380 | 450 |
| D2(H9) | 75 | 90 | 75 | 125 | 150 | 180 | 220 | 280 | 300 | 360 |
| h1 | 2 | 3 | ||||||||
| f | 5 | 6 | 8 | |||||||
| h | 6 | 8 | 6 | 10 | 12 | 14 | 16 | 20 | 25 | 30 |
| b | 10 | 12 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 |
| d1 | 20 | 30 | 26 | 42 | 50 | 62 | 65 | 80 | 85 | 105 |
| d2 | 28 | 45 | 39 | 58 | 72 | 82 | 98 | 118 | 128 | 158 |
| d | M8 | M10 | M8 | M12 | ∮18 | ∮22 | ∮26 | ∮22 | ∮26 | ∮33 |
| n | 4 | 8 | ||||||||
Table 61-3 connection form and size
| Flange connection type and dimensions | |||||||||||
![]() |
Code position 6, 7 | 10 | 11, 12 | 20 | 21, 22 | 30 | 31, 32 | 40 | 41, 50 | 51, 60 | 61 |
| Flange No. | F07 | F10 | F14 | F16 | F25 | F30 | F35 | F40 | |||
| d1 | 90 | 120 | 175 | 205 | 300 | 350 | 415 | 475 | |||
| d2(f8) | 55 | 70 | 100 | 130 | 200 | 230 | 260 | 300 | |||
| d3 | 70 | 102 | 140 | 165 | 254 | 298 | 356 | 406 | |||
| d4 | M8 | M10 | M16 | M20 | M16 | M20 | M30 | M36 | |||
| h | 20 | 20 | 25 | 30 | 30 | 30 | 45 | 54 | |||
| h1 | 3 | 3 | 4 | 5 | 5 | 5 | 5 | 8 | |||
| n | 4 | 8 | |||||||||
| Form and dimensions of output shaft end | |||||||||||
![]() |
Code position 6, 7 | 10 | 11, 12 | 20 | 21, 22 | 30 | 31, 32 | 40 | 41, 50 | 51, 60 | 61 |
| Flange No. | F07 | F10 | F14 | F16 | F25 | F30 | F35 | F40 | |||
| d5 | 32 | 53 | 53 | 72 | 72 | ||||||
| d6 | 30 | 50 | 50 | 70 | 70 | ||||||
| L | 40 | 54 | 54 | 75 | 75 | ||||||
| h | 40 | 79 | 54 | 97 | 76 | ||||||
![]() |
d5 | 25 | 32 | 32 | 53 | 53 | 75 | 115 | 115 | 178 | 190 |
| d7(h9) | 28 | 42 | 42 | 60 | 60 | 80 | 100 | 120 | 160 | 180 | |
| b1(js9) | 8 | 12 | 12 | 18 | 18 | 22 | 28 | 32 | 40 | 45 | |
| t1(+0.2) | 31.3 | 45.3 | 45.3 | 64.4 | 64.4 | 85.4 | 106.4 | 127.4 | 169.4 | 190.4 | |
| h1 | 1.2 | 1.3 | 1.3 | 2.1 | 2.1 | 2.1 | 2 | 3 | 3 | 5 | |
| L | 36 | 46 | 46 | 67 | 67 | 82 | 139 | 139 | 180 | 207 | |
![]() |
d10(H9) | 16 | 20 | 20 | 30 | 30 | 40 | 50 | 60 | ||
| b4(js9) | 5 | 6 | 6 | 8 | 8 | 12 | 14 | 18 | |||
| t3(+0.2) | 18.3 | 22.8 | 22.8 | 33.3 | 33.3 | 43.3 | 53.3 | 64.4 | |||
| h1 | 3 | 3 | 3 | 4 | 4 | 5 | 5 | 5 | |||
| L | 35 | 45 | 45 | 65 | 65 | 80 | 110 | 130 | |||
1.2.4. See table 61-4 for output shaft speed (code position 9).
Table 61-4 output shaft speed (code position 9)
| Code position 9 | Output speed | Default factory settings | Output torque range(N·m) | |
| (r/min) | (r/min) | S series(switch type) | R series(adjusting type) | |
| B | 1~8 | 3.5 | 3200~10000 | |
| C | 2~16 | 7 | 800~2500, 1600~5000 | 800~1600 |
| D | 5~40 | 20 | 10~30, 20~60, 50~150, 100~300, 200~600, 400~1200 | 10~20, 20~40, 50~100, 100~200, 200~400, 400~800 |
| E | 10~80 | 40 | 10~30, 20~60, 50~150, 100~300, 200~600, 400~1200 | |
| F | 20~160 | 80 | 10~30, 20~60, 50~150, 100~300, 200~600 | |
1.2.5. Power supply (code position 10)
A:380VAC、50Hz;
B: 220 VAC, 50 Hz (only applicable to torque in table 61-5).
Table 61-5 torque range of output shaft
| Series | Output torque range | ||
| S series(switch type) | 10~30 | 20~60 | 50~150 |
| R series(adjusting type) | 10~20 | 20~40 | 50~100 |
Z: Others.
1.2.6. Control module selection (code position 11)
0: frequency conversion control module;
1: Non frequency conversion control module.
1.2.7. Protection sleeve of valve stem (code position 12). See table 61-6 for the length of valve stem protective sleeve
Table 61-6 Length of the protection sleeve of valve stem mm
| Code position 12 | 2SA81 | 2SA82 | 2SA832~SA86 |
| 0 | Protection sleeve without stem | ||
| 1 | 250 | 500 | 750 |
| 2 | 500 | 700 | 1000 |
| 3 | Special stem protection sleeve | ||
1.2.8 PID regulation module (code position 13).
0: no PID control module;
1: There is PID control module.
1.2.9. Bus communication (code position 14).
0: no bus communication;
1: Bus communication, single channel;
2: There is bus communication, dual channel.
1.2.10. code position 15 and 16: spare code position is 0.
1.3. Structural features
2SA8 series electric actuator consists of special motor, worm gear reducer with pistol, hand electric switching mechanism, electric actuator connecting part and electric part. 2SA8 adopts the advanced frequency conversion technology to control the motor, which saves the complex mechanical stroke and torque control mechanism, and uses the digital sensor to measure the position, so as to simplify the mechanical structure, make the structure compact, and make the debugging and installation simple and convenient.
2. Main technical parameters and product appearance
2.1. Main technical parameters (see table 61-7 and table 61-8)
Table 61-7 Performance parameters of 2SA80 series electric actuator
| Model 2SA | 8010 | 8011 | 8012 | 8020 | 8021 | 8022 | 8030 | 8031 | 8032 | 8040 | 8041 | 8050 | 8051 | 8060 | 8061 | ||||||||||||||||||
| Control torque (N.m) | Max. | 30 | 60 | 150 | 300 | 600 | 1200 | 2500 | 5000 | 10000 | |||||||||||||||||||||||
| Min. | 10 | 20 | 50 | 100 | 200 | 400 | 800 | 1600 | 3200 | ||||||||||||||||||||||||
| Flange No. GB12222 (ISO5120) |
F07 | F10 | F14 | F16 | F25 | F30 | F35 | F40 | |||||||||||||||||||||||||
| Output speed (r/min) | 5~160 | 5~80 | 2~16 | 1~8 | |||||||||||||||||||||||||||||
| Working system | S2, 15min | ||||||||||||||||||||||||||||||||
| Weight(Kg) | 30 | 50 | 115 | 160 | 305 | 410 | |||||||||||||||||||||||||||
| Motor | Variable frequency motor, insulation class F | ||||||||||||||||||||||||||||||||
| Output speed and motor power (kW) | B | 1~8 | 380, AC, 50HZ |
9 | |||||||||||||||||||||||||||||
| C | 2~16 | 4 | 9 | ||||||||||||||||||||||||||||||
| D | 5~40 | 0.18 | 0.37 | 0.75 | 1.1 | 3 | 5 | ||||||||||||||||||||||||||
| E | 10~80 | 0.37 | 0.55 | 1.5 | 2.2 | 5 | 9 | ||||||||||||||||||||||||||
| F | 20~160 | 0.55 | 1.5 | 2.2 | 4 | 9 | |||||||||||||||||||||||||||
| D | 5~40 | 380, AC, 50HZ |
0.18 | 0.37 | 0.75 | ||||||||||||||||||||||||||||
| E | 10~80 | 0.37 | 0.55 | 1.5 | |||||||||||||||||||||||||||||
| F | 20~160 | 0.55 | 1.5 | 2.2 | |||||||||||||||||||||||||||||
Table 61-8 performance parameters of 2SA85 series electric actuators
| Model 2SA | 8510 | 8511 | 8512 | 8520 | 8521 | 8522 | 8530 | 8531 | 8532 | 8540 | 8541 | ||||||||||||||
| Control torque (N.m) | Max. | 20 | 40 | 100 | 200 | 400 | 800 | 1600 | |||||||||||||||||
| Min. | 10 | 20 | 50 | 100 | 200 | 400 | 800 | ||||||||||||||||||
| Flange No. GB12222 (ISO5120) |
F07 | F10 | F14 | F16 | F25 | F30 | |||||||||||||||||||
| Output speed (r/min) | 5~40 | 2~16 | |||||||||||||||||||||||
| Working system | S5 | ||||||||||||||||||||||||
| Weight(Kg) | 30 | 50 | 115 | 160 | |||||||||||||||||||||
| Motor | Variable frequency motor, insulation class F | ||||||||||||||||||||||||
| Output speed and motor power (kW) | D | 5~40 | 380V AC, 50HZ | 0.18 | 0.37 | 0.75 | 1.1 | 3 | 5 | 4 | 4 | ||||||||||||||
| D | 5~40 | 220V AC, 50HZ | 0.18 | 0.37 | 0.75 | ||||||||||||||||||||
2.2. Product appearance
See figure 61-1, table 61-9, figure 61-2 and table 61-10 for the outline and corresponding dimensions of 2SA8 series multi turn electric actuator

Table 61-9 overall dimensions of 2SA81 ~ 2SA83 electric actuators
| Model | A | a1 | a2 | B | b1 | b2 | ∮C | H | h1 | h2 |
| 2SA81 | 502 | 374 | 128 | 584 | 278 | 306 | 256 | 268 | 115 | 150 |
| 2SA82 | 638 | 402 | 236 | 675 | 348 | 327 | 472 | 304 | 127 | 172 |
| 2SA83 | 723 | 454 | 269 | 872 | 540 | 332 | 538 | 388 | 128 | 218 |

Table 61-10 outline dimensions of 2SA84 ~ 2SA86 electric actuator
| Model | A | a1 | a2 | B | b1 | b2 | b3 | ∮C | H | h1 | h2 |
| 2SA84 | 679 | 402 | 277 | 817 | 191 | 299 | 327 | 472 | 526 | 347 | 179 |
| 2SA85 | 762 | 454 | 308 | 900 | 215 | 353 | 332 | 538 | 670 | 442 | 228 |
| 2SA86 | 809 | 454 | 355 | 940 | 208 | 400 | 332 | 538 | 800 | 472 | 328 |