Anode plate for ESP

Anode plate is the core component of electrostatic precipitator. The acceptance standard of anode plate is flat, high strength, strong stiffness and not easy to twist. The electrolytic anode plate is composed of anode lug, transition row and main board welded in sequence. This encyclopedia will introduce you to the price of anode plate, the purpose of anode plate, the introduction of anode plate manufacturer, anode plate material and other information.

key word:Heat exchange element


Product description

1. Anode plate process

Anode plate is the core component of electrostatic precipitator. The acceptance standard of anode plate is flat, high strength, strong stiffness and not easy to twist. The electrolytic anode plate is composed of anode lug, transition row and main board welded in sequence. This encyclopedia will introduce you to the price of anode plate, the purpose of anode plate, the introduction of anode plate manufacturer, anode plate material and other information.

Generally speaking, after the residual anode is out of the groove, the anode mud on it can be stripped and washed, and then melted and cast into an anode. Some residual anode can also be used for other purposes. For example, copper residual anode can be added to converter as cold material or used as raw material for manufacturing copper sulfate; Nickel residual anode can be used to manufacture electrolyte to supplement nickel ions.

A high-voltage electric field is formed between the cathode line of the anode plate connected to the high-voltage DC power supply and the grounded anode plate. Due to the corona discharge of the cathode, the gas is ionized, and the negatively charged gas ions move to the anode plate under the action of the electric field force. If they collide with the dust particles during the movement, the dust particles will be negatively charged, and the charged dust particles will also move to the anode under the action of the electric field force, After reaching the anode, the negative charge is released, the dust particles are deposited on the anode plate, and the purified gas is discharged out of the duster.

The electrolytic anode plate is composed of anode lug, transition row and main board by sequential welding. It is characterized in that the transition row is composed of tin, silver, cobalt, silicon, antimony and lead. The main board is composed of calcium, aluminum, silver, tin and lead in proportion, and added with trace rare earth elements, which are respectively dissolved, mixed, cast, cold pressed, sheared and stamped. Good corrosion resistance, used for electrolytic manganese.

The electrophoretic anode plate must be clean and transparent, especially in the weeks before the new tank is put into the tank, pay special attention to the color of the anode solution. If it changes color soon, it indicates that there is a problem with the anode system; If the anode solution becomes blurred, the anode film may be damaged or contaminated by bacteria; If the color of the anode solution becomes close to that of the bath solution, the anode film may be damaged; If the color of the anode solution turns brown or black, but it is still transparent, it indicates that the stainless steel anode plate corrodes too fast, or the flow is low, or the conductivity is too high. In case of leakage or damage of anode unit, stop the anode pump immediately, close the rectifier if necessary, and replace the leaking anode unit in time. The power supply must be turned off before replacing the anode. The specific operations are as follows: close the circulating pump of the anode solution system and close the rectifier; Check all anode units and find out the leaking anode units; Isolate the leaking anode unit from the electrophoresis system; Replace the leaking anode unit. The anode unit and anode film shall be washed after the electrophoretic tank is switched. After the tank is switched, deionized water shall be continuously sprayed on the anode film of the electrophoretic anode plate to prevent the electrophoretic paint from drying on the anode film and drying through the anode film. Maintenance of electrophoretic coating anode system here, attention shall be paid to the detection of bacterial grade, bacterial control method and sterilization operation method of pure water system used in the workshop. Bacteria are easily attached to the tank wall and the inner surface of the pipeline, especially the inlet and outlet pipes of the polar tube and the regulating valve, which are easily blocked by bacterial dirt due to the influence of reducing diameter. Importantly, bacteria also have a potential impact on the conductivity of anode solution and coating quality.

Electrophoretic anode plate is characterized by high voltage and low current. Therefore, the requirements for rectifier power supply are 0-220V (or 0-100V) continuous adjustment, voltage stabilization (waveform fluctuation is less than 5%), and time control device (0-5min). At present, many domestic manufacturers have produced rectifier power supplies specially suitable for electrophoretic painting. The hanger used for electrophoretic painting must be firmly contacted and have good conductivity. The hook part is generally made of spring steel wire and easy to disassemble and replace. The hanger shall be designed to facilitate cleaning. For deep hole parts, the paint solution in the hole shall be used, which can be recycled during cleaning, which is beneficial to prolong the service life of the paint solution and reduce the production cost. Anode system is an indispensable part of cathodic electrophoretic coating. The performance and price of anode have a great impact on the process quality and coating cost of electrophoretic anode plate. The maintenance and repair of anode has also become one of the important issues concerned by the industry.

Sterilization control scheme for the anode system of electrophoresis anode plate: the anode system has been analyzed for many times after bacteria are generated. Except for the bacteria in the anode solution box, if the bacterial index of other samples is less than 1*102. The bacterial index meets the requirements. If the bacterial index in the anode solution box exceeds the standard, it is as high as 8.0 * 105 is close to 106, and molds (molds) and other bacteria are easy to grow. We can take the following measures to control the results: the cleaning scheme should be determined according to the bacterial growth in the anode sterilization step, and the general step scheme is: periodic use of bactericide; Regularly clean the bacterial dirt on the pipeline, valve, anode tank wall and tank bottom; Inject pure water for circulating cleaning; Prepare anode solution with acetic acid after cleaning. The specific frequency of releasing bactericide and manual cleaning of electrophoresis anode plate shall be determined according to the bacterial test report of anode solution. In the conventional bactericide sterilization scheme, when the conventional bactericide of electrophoretic paint manufacturer is used, it is recommended to use the special bactericide Kathon lxe, which is a broad-spectrum and non oxygen bactericide. It can effectively kill a wide range of microorganisms at low concentration, and the active molecules contained can be degraded to reduce the emission problem. It shall be implemented according to the following detailed scheme: disassemble the pipes and valves, and use special tools to clean the bacterial dirt at the pipes and valves

 

2. Basic type of anode plate (see Fig.1)

1

 

3. Dimension deviation and shape deviation of anode plate (see Fig. 2, Fig. 3 and Table 1)

1

 

Table 1

Deviation category Name of deviation item Deviation code Anode plate width
500 >500
Dimensional deviation Outline dimensions Length L l ±5
Wdith B b t ±2
Height H h ±1 35
Mounting hole distance Length direction L0 l0 ±1
Width direction B0 b0 ±05
Shape deviation Length direction L Plane curvature f L/1000 and 10
Side curvature g 0.5L/1000 and 5
Plane twist e 1.5L/1000 and 15
Plane waviness q 1.5/200 any section

 

 

4. Series of anode plate

Based on the design of different requirement, we provide normal 818C, 735C, 590C, 460C, 390C, ZT40, 385Z; and enhanced 480C (A), 480C (B), 385Z, ZT-24, 470C, 485Z, 590C, 590Z, 735Z, 480 with small waves.